1
F o r S h a r p C a r o u s e l
®
B u i l t - i n K i t
M o d e l s R K - 4 2 S 2 4 , R K - 5 1 S 2 7 ,
R K - 5 1 K 3 0 , R K - 5 1 S 3 0 o r R K - 5 1 W 3 0 .
THIS KIT IS UL APPROVED TO ALLOW CERTAIN MICROWAVE OVENS
TO BE INSTALLED ABOVE CERTAIN CONVENTIONAL/CONVECTION
WALL OVENS. PLEASE SEE THE OPERATION MANUAL REGARDING
APPROVED BUILT-IN APPLICATIONS.
I N S T A L L A T I O N I N S T R U C T I O N S
3
®
1
2
4
5
6
7
NO.
PART NAME
QTY
PART CODE
1
FRAME ASSEMBLY
1
S24
- FDECAB015MRY0
S27
- FDECAB008MRY0
S30
- FDECAB018MRY0
K30
- FDECAB019MRY0
W30 - FDECAB020MRY0
2
EXHAUST DUCT ASSEMBLY
1
S24
- FDUC-B019MRK0
S27
- FDUC-B032MRK0
S30
- FDUC-B032MRK0
K30
- FDUC-B032MRK0
W30 - FDUC-B032MRK0
3
POWER SUPPLY CORD
1
BOX ASSEMBLY
FCOVHB004MRK0
4
REAR DUCT
1
PDUC-B072MRP0
5
SCREW A
3
XCTSD40P10000
6
SCREW B
2
XTTSD40P30000
7
SCREW C
4
S24
- LX-CZB012MRE0
S27
- LX-CZB012MRE0
S30
- LX-CZB012MRE0
K30
- LX-CZB014MRE0
W30 - LX-CZB015MRE0
IMPORTANT :
This Built-in Kit is designed for and approved only for those Sharp
Microwave Ovens specifying Built-In Kit RK-42S24, RK-51S27, RK-51K30,
RK-51S30 or RK-51W30 on the rating label on the left side wall of the
oven cavity.
The cabinet or wall opening must be within the following dimensions:
RK-42S24
HEIGHT
: 15
11
/
16
" to 16"
WIDTH
: 22
1
/
16
" to 22
3
/
8
"
DEPTH
: minimum 19
1
/
4
"
*RK-51S27, *RK-51K30,
HEIGHT
: 16
3
/
4
" to 17"
*RK-51S30 & *RK-51W30
WIDTH
: 24
3
/
8
" to 24
11
/
16
"
DEPTH
: minimum 20"
* IF YOUR LOWER CONVENTIONAL OVEN IS NOT LISTED IN THE OPERATION MANUAL OF
THE MICROWAVE OVEN AS AN APPROVED MAKE AND MODEL, THEN DO NOT INSTALL
THE MICROWAVE OVEN ABOVE IT OR IN ANY AREA WHERE HEAT AND STEAM ARE
GENERATED; FOR EXAMPLE, NEXT TO OR ABOVE A CONVENTIONAL RANGE.
S= Stainless, K=Black, W=White
PLEASE READ THESE INSTRUCTIONS THOROUGHLY BEFORE
BEGINNING INSTALLATION!
•
Be sure to DISCONNECT THE PLUG of the microwave oven from the
electrical outlet before installing the Built-in Kit. Remove the Carousel
turntable from the oven cavity.
•
Because the kit includes metal parts, due caution should be used in
handling and installation to avoid the possibility of injury.