– 11 –
CD-BA120/125
How to remove the pickup (See Fig. 11-2)
1. Remove the screws (B1) x 2 pcs., to remove the shaft (B2).
2. Remove the stop washer (B3) x 1 pc., to remove the gear
(B4).
3. Remove the pickup.
Figure 11-2
CD MECHANISM SECTION
Perform steps 1, 2, 3, 9, 12 and 13 of the disassembly method
to remove the CD mechanism.
How to remove the loading motor
(See Fig. 11-1)
1. Bend the hooks (A1) x 5 pcs., to remove the loading motor.
Figure 11-1
Note
After removing the connector for the optical pickup from the
connector wrap the conductive aluminium foil around the front
end of connector so as to protect the optical pickup from
electrostatic damage.
(A1)x2
(A1)x1
Loading Motor
CD Base
(A1)x2
(B1) x2
ø2.6 x6mm
Shaft
(B2) x1
Stop Washer
(B3) x1
Gear
(B4) x1
CD Mechanism
Pickup
ADJUSTMENT
MECHANISM SECTION
•
Driving Force Check
Torque Meter
Specified Value
Play: TW-2111
Tape 1: Over 80 g
Tape 2: Over 80 g
•
Torque Check
Torque Meter
Tape 2
Play: TW-2111
30 to 80 g. cm
30 to 80 g.cm
Fast forward: TW-2231
—
70 to 180 g.cm
Rewind: TW-2231
—
70 to 180 g.cm
Specified Value
Tape 1
Specified
Value
Adjusting
Point
Instrument
Connection
Test Tape
Normal
MTT-111
Variable
3,000
±
Speaker
speed
Resistor in
30 Hz
terminal
motor.
(Load
resistance:
6 ohms)
•
Tape Speed
Figure 11-3
TAPE MECHANISM
Motor
Variable Resistor in motor