CD-G10000/CP-G10000S
2 – 3
Sliding the PICKUP with<<
>>, <<
>> button must only be
in STOP mode.
<<MEMORY>> key input.
Laser ON.
<<MEMORY>> key input.
Tracking OFF play at that specific point.
<<MEMORY>> key input.
Tracking ON play from that specific point.
<<MEMORY>> key input.
Adjustment result automatically will display as below for each 2 sec:
a) “FOF_XXXX”
b) “TOF_XXXX”
c) “TBAL_XX”
d) “TGAN_XX”
f) “FGAN_XX”
g) “RFLS_XX”
<<STOP>> key input.
STOP
explanation:
a) Focus off set
= “FOF_XXXX”
b)Tracking off set
= “TOF_XXXX”
c)Tracking balance
= “TBAL_XX”
d)Tracking Gain
= “TGAN_XX”
f) Focus Gain
= “FGAN_XX”
g) RF level shift
= “RFLS_XX”
VOL — Last memory
P.GEQ — FLAT
X-BASS — OFF
To cancel: Power OFF