– 15 –
MD-MX30/MX30W
Table 15-1 Test mode entry
TEST MODE
Press specified buttons simultaneously to enter the following test modes.
System section
TEST 1: Factory setting (version number and destination)
TEST 2: Soft reset
MD section
TEST 3: MD test 1 (adjustment, test, etc.)
CD section
TEST 4: CD test
Tuner section
TEST 5: Tuner test frequency preset
TEST 6: Tuner preset clear
Entering the test mode
While holding down the following 2 buttons, press the ON/STAND-BY button to enter each test mode.
System section
TEST 1 Factory setting test mode
Object:
Putting the unit in default state.
Function:
Checking existence of CD and MD and reinitializing all functions.
Operation: The unit performs CD initial operation and checks existence of CD.
If a CD exists, "CD OPEN" appears and tray opens in CD mode then the unit enters the normal power-on state.
Ejecting MD
While disc existence check, program version and preset destination appear according to the display.
When disc existence check is completed, the unit reinitializes all settings and displays "FINISH" according to the display and
prohibits every button input including power supply operation.
Leaving the test mode
The unit returns to normal operation by connecting and disconnecting the power supply cord.
Destination is displayed by its name.
Table 15-2 Character display
Item
Version and destination display
CD presence
Setting end
Operation
Function
Sub-display
1
2
3
4
5
6
7
8
:
9
10
V
H
Number
:
C
D
O
P
E
N
F
I
N
I
S
H
Sub-display
Type
Remarks
Character display
*
* *
Name
Description
Button1
Button2
Level meter
"Center Bar"
TEST1
TEST2
TEST3
TEST4
TEST5
TEST6
Factory setting
Soft reset
MD test 1
CD test
Tuner test
Frequency preset
Tuner preset clear
Setting the unit to default.
Reinitializing the unit.
Setting MD microcomputer to test mode
Testing CD mechanism, hard
Presetting test frequency
Clearing all preset settings
[SURROUND]
[SURROUND]
[SURROUND]
[X-BASS]
[TUNER]
[TUNER]
[ENTER]
[DELETE]
[MD-PLAY]
[>>]
[MD-PLAY]
[MD-STOP]
–
–
Flashing
Flashing
–
–