44
■
PLU level shift (for direct PLUs)
NOTE
To use this function on ER-A411, consult your authorized SHARP dealer.
This shift can double or triple the number of direct PLUs on your register without adding additional direct PLU
keys. You can use direct PLUs in three levels by utilizing the
key or PLU level shift keys
\
through
]
.
Level key shifts the PLU level from the other two to the required level. (The normal level is the level 1.)
You must program your machine in the PGM2 mode to select one of the two PLU level shift modes —
automatic return mode* and lock shift mode** — and decide whether to allow PLU level shift in both the
REG and MGR modes or in the MGR mode alone.
* The automatic return mode automatically shifts the PLU level back to level 1 after pressing a direct PLU
key or
fi
nalizing each transaction (either can be selected in the PGM2 mode).
** The lock shift mode holds the current PLU level until depression of a PLU level shift key.
Automatic return mode (for PLU levels)
If your register has been programmed for PLU level in the automatic return mode, press a desired PLU level
shift key before a numeric entry.
Procedure
Direct PLU
(Finalization)
(Q’ty, )
Numeric entry
Direct PLU
Return to level 1
(Q’ty, )
Numeric entry
(Returning every item entry)
(Returning every transaction)
n: PLU shift no. (1 through 3)
through
n
L3
L1
LEVEL
#
through
n
L3
L1
LEVEL
#
NOTE
When you use the FF method, you need not press the
@
key for multiplication entries.
Lock shift mode (for PLU levels)
If your register has been programmed for PLU level in the lock shift mode, press a desired PLU level shift
key before a numeric entry.
Procedure
n: PLU shift no. (1 through 3)
Direct PLU
Stay in the current level
(Q’ty, )
Numeric entry
through
n
L3
L1
LEVEL
#
NOTE
When you use the FF method, you need not press the
@
key for multiplication entries.
Summary of Contents for ER-A411
Page 1: ...ELECTRONIC CASH REGISTER FULL DETAILED INSTRUCTION MANUAL MODEL ER A411 ER A421 ...
Page 197: ...197 Optional features PGM2 mode Report title Setting Item ...
Page 198: ...198 Report PGM2 mode Report title Setting Item ...
Page 199: ...199 Function text PGM2 mode Report title Text Function text default ...
Page 224: ......
Page 226: ...14G A411A421VIME1 ...