CHAPTER 7. SERVICE PRECAUTION
1. Error code table
When the following error codes are displayed, press the
key and take a proper action according to the table below.
Error
code
Error status
Action
E01
Registration error
Make a correct key entry.
E02
Misoperation error
Make a correct key entry.
E03
Undefined code is entered.
Enter a correct code, or declare it by the programming.
E04
Joumal paper is nearly empty.
Replace joumal paper roll with a new one.
E05
Secret code error
Enter a correct secret code.
E07
Memory is full.
Expand the file within the capacity of memory.
E08
Insert slip paper.
Insert slip paper.
E09
Invalid cashier code is enterd.
Enter a correct cashier code.
E11
Compulsory depression of the
key for direct finalization
Press the
key and continue the operation.
E12
Compulsory tendering
Make a tendering operation.
E13
Compulsory of PBLU entry
Make a PBLU entry.
E16
Check digit error
Enter a correct code.
E26
File type error
E31
Compulsory non-add code entry
Enter a non-add code.
E32
No entry of your cashier code.
Make a cashier code entry.
E33
The current cashier code should not be changed.
Change a cashier after finalizing the transaction.
E34
Overflow limitation error
Make a registration within a limit of entry.
E35
The open price entry is inhibited.
Make a preset price entry.
E36
The perset price entry is inhibited.
Make an open price entry.
E37
Ther direct finalization is inhibited.
Make a tendering operation.
E38
Read error of scale
E67
Registration buffer is full.
E76
The drawer is still opened.
Close the drawer.
E77
Price shift error
E79
Reading of undefined vendor coupon UPC
E86
Communication error at ECR copy
E87
Data format error at ECR copy
E88
Time out error at ECR copy
E94
Age verification error
2. Conditions for soldering circuit parts
To solder the following parts manually, follow the conditions described below.
PARTS NAME
PARTS CODE
LOCATION
CONDITIONS FOR SOLDERING
Front LED (HDSP5621)
Front LED PWB: FND1-5
315°C/2 sec.
Pop-up LED (HDSP-F501#S02)
Pop-up LED PWB: FND1-10
315°C/2 sec.
3. Caution to be taken when removing the TOP CABINET
After removing the ER-A450T’s TOP CABINET, put the TOP CABINET on the positions given below to prevent the cable that connects the MAIN
PWB and POWER SUPPLY PWB from disconnecting.
1) Put the TOP CABINET on the left of the DRAWER CABINET.
Put a sheet on the DRAWER CABINET and put the TOP CABI-
NET upright on the sheet, as shown below.
2) Put the TOP CABINET behind the drawer
Put a base (proper height) behind the drawer and put the TOP
CABINET upright on the base, as shown below.
Drawer
cabinet
Power transformer
Power supply PWB
Cable
Main PWB
Top cabinet
Sheet
[ Front view ]
Main PWB
Base
Drawer
cabinet
Power supply PWB
Power transformer
[ Right side view ]
Cable
Top
cabinet
7 – 1
Summary of Contents for ER-A450T
Page 56: ...2 MAIN PWB LAYOUT 1 SIDE A ...
Page 57: ... 2 SIDE B ...
Page 59: ...4 FRONT DISPLAY PWB LAYOUT 5 POP UP DISPLAY PWB LAYOUT ...
Page 61: ...7 PS PWB LAYOUT ...