background image

中文

C-11

6

將過濾網支架裝進主機。

7

在日期標籤上填寫開始使用
的日期。

該日期將作為日後過濾網更換時間
的參考之用。

8

將前面板裝進主機。

9

將電源插座插入牆上的插座
內﹐並使用遙控器啟動或停
止操作。

日期標籤

爪形槽

插爪

過濾網支架

前面板

Summary of Contents for FU-28H-A

Page 1: ...中文 FU 28H A AIR PURIFIER INSTALLATION MANUAL OPERATION MANUAL R Plasmacluster is a trademark of Sharp Corporation ENGLISH 空氣清新機 安裝說明書 使用說明書 Wall mountingtype 壁掛型 Plasmacluster是聲寶公司的商標 ...

Page 2: ......

Page 3: ...KS An air purifier draws in room air from its air intake lets the air pass through an Active Carbon Filter Deodorizing Filter and a HEPA Filter dust collec tion filter inside the unit then dis charges the air from its air outlet The air purifier repeats this process by moving its internal fan As air passes through the HEPA Filter can remove dust particles The Active Carbon Filter gradually absorbs...

Page 4: ...or similarly qualified person in order to avoid a hazard Do not operate when using aerosol insecticides or in rooms where there is oily residue incense sparks from lit cigarettes chemical fumes in the air or a humidity condition Use care when cleaning the air purifier Strong corrosive cleansers may damage the exterior Only Sharp Authorized Servicers should service this air purifier Contact the nea...

Page 5: ...s where the unit is exposed to condensation due to drastic temperature changes Place on a stable surface with sufficient air circulation Install the unit on a wall wooden pillar crosspiece etc that is flat and strong enough Do not install the unit on a thin wall or on plasterboard The unit may fall down if installed on an insufficiently strong wall To install the unit on a wooden wall that is less...

Page 6: ...Odour Sensor Filter Frame HEPA Filter white with Microbial Control Filter blue Active Carbon Filter Deodorizing Filter Stainless Steel Pre Filter Front Panel BACK Power Cord Adjusting Guide Power Cord Power Plug ACCESSORIES Remote Control 1 unit Battery AA battery x 2 Operation Manual Wall mounting kit Wall mounting bracket Wood screws 4 pcs Fisher plugs 4 pcs Air Outlet Shape of plug depends on c...

Page 7: ...ttery fluid leakage The batteries of the accessory are for initial use only and may be depleted within 1 year INSERTING BATTERIES IN THE REMOTE CONTROL 1 Remove the back cover Press and slide the back cover to remove 2 Insert batteries Insert batteries with and as shown below 3 Close the back cover PREPARATION REMOTE CONTROL USE Operate the remote control facing the main unit receiver The signal r...

Page 8: ...it Then fix the wall mounting bracket through screw holes with the supplied wood screws Install the unit on a wall wooden pillar crosspiece or the like that is flat and strong enough If the wall is weak or made of concrete have the unit installed by a specialist such as an electric appliance store Avoid locations near inverter lamps or where the unit is exposed to direct sunlight 1 Determine the m...

Page 9: ...den surface Use wood screws for installation E 7 Install on a wooden pillar φ5mm 35mm Install on a wooden crosspiece Wood screws 4 Wooden pillar Caution To install the unit on a wooden wall that is less than 10 mm thick consult your dealer and have them confirm the strength of the wall before installation Install the unit on a wall wooden pillar crosspiece etc that is flat and strong enough Make s...

Page 10: ...o remove the front panel and filter frame E 8 INSTALLATION In case the power plug to be lead to the left of the unit Do not wire the power cord right below the wall mounting bracket Power cord adjusting guide In case the power plug to be lead to the right of the unit Cautions To avoid scratching or damaging the unit place it on a soft piece of cloth until it is installed on the wall Do not lead th...

Page 11: ...es 5 Double check the installation Make sure that the claws of the unit are hooked in properly If they are not the unit will move sideways In addition the unit may fall off the wall and be damaged Make sure that the power cord is not caught in the unit 6 Remove the mark Wall mounting bracket HOW TO REMOVE THE UNIT Pull the power plug out of the wall outlet and remove the Front Panel and Filter Fra...

Page 12: ...ot operate properly 4 Place the Active Carbon Filter within the Filter Frame on top of the HEPA Filter The Active Carbon Filter does not have a front and a back 5 Next place the Pre Filter within the Filter Frame Fit the 4 tabs of the Pre Filter into the holes in the Filter Frame E 10 FILTER INSTALLATION Tabs Pre Filter Active Carbon Filter HEPA Filter Filter Frame HEPA Filter Filter Frame Pre Fil...

Page 13: ...tart date on the Date Label Use the date as a guide for the Filter Replacement schedule 8 Mount the Front Panel to the main unit 9 Insert the power plug into the wall outlet and check on off operation using the remote control Date Label Claw socket Claw Filter Frame Front Panel ...

Page 14: ...he set timer switches every time the button is pressed as shown below When 4 hours is selected 4 H indicator light activates When the remaining time becomes 1 hour then indicator light switches to 1 H E 12 For the first 30 seconds after the plug is inserted into the wall outlet the unit will check the conditions of the air Silent Max AUTO 1 hour 4 hours Cancel Auto Operation Odour sensor checks th...

Page 15: ...d button The fan speed can be switched between Silent Max OFF Timer button The set timer switches every time the button is pressed as shown below When 4 hours is selected 4 H indicator light activates When the remaining time becomes 1 hour then indicator light switches to 1 H REMOTE CONTROL OPERATION Silent Max 1 hour 4 hours Cancel Plasmacluster Ion Operation While the product is in operation the...

Page 16: ...f compared with that of new filters HEPA Filter About 12 months after opening Active Carbon Filter About 12 months after opening REPLACING THE FILTERS 1 See page E 10 11 for directions on how to install the filters when replacing 2 Fill in the usage start date of the filters on the Date Label Replacement Filters Model FZ 28SEF HEPA Filter with Microbial Corbon Filter 1 unit Active Carbon Filter 1 ...

Page 17: ...etc and cold warm water Metal brushes or scrub brushes may cause damage After washing leave it in the shade until it gets dried Then place it back to the Filter Frame SPECIFICATIONS The applicable floor surface area is the surface area for when operating the unit in MAX fan level Applicable floor surface area indicates the space where a certain amount of dust pollution can be removed in 30 minutes...

Page 18: ...led Replace filters Refer to E 14 Plasmacluster Air Purifiers emit small traces of ozone which may produce an odour These ozone emissions are below safety levels set by the IEC 60335 2 65 Is the unit installed in a location that is difficult for the sensor to detect cigarette smoke Are the odour sensor openings blocked or clogged In this case clean the openings Refer to E 15 The unit does not oper...

Page 19: ...多謝您購買聲寶FU 28H A空氣清新機 請仔細 閱讀此說明書 以了解正確的使用信息 在使 用本產品之前 請務必閱讀 重要安全事項 這一節 閱讀後請妥善保管此說明書 以便日 後翻閱 聲寶空氣清新機操作原理 空氣清新機經進氣口吸入室內空氣 使其通過機內的活性碳過濾網 除臭 過濾網 和HEPA過濾網 集塵過濾 網 然後從排氣口排出 空氣清新 機通過其內部風扇的操作不斷重複此 過程 當空氣通過時 HEPA過濾網 能夠除去灰塵粒子 當異味成分多次 通過活性碳過濾網時 便逐步被吸 收 異味成分也被HEPA過濾網吸 收 有些已被過濾網吸附的異味分子可能 會離開過濾網 然後隨出風口吹出 根據不同的使用環境 這些異味可能 在比預期更短的時間內變得強烈 在 這種情況下 請選購過濾網更換配件 FZ 28SEF 注意 本空氣清新機用於去除空氣中懸浮的 灰塵和異味 而不能去除有害氣體 如 香 煙 煙 霧 中 含 ...

Page 20: ...掉插頭 否則可能導致因絕緣不良引起的電擊和 或因短路引起的火災 如果電源線損壞 必須由生產商或其代理 聲寶公司的特約維修中心或具有相同資格的人員來更換 以免 發生危險 當使用噴霧殺蟲劑時請勿使用本機 或若房間內有油渣 焚香時的煙 點燃香煙的火苗 空氣中的化學氣 體或濕氣重時也不要使用本機 清潔空氣清新機時請加以小心 腐蝕性強的清潔劑會損壞本機的表面 只有聲寶特約維修人員才能維修本空氣清新機 當需要調整 修理或有任何問題時 請聯絡就近的維修人 員 電池處理前必須從遙控器中取出 並且必須安全處理 操作本機的注意事項 請勿堵塞進氣口和排氣口 不要靠近或在熱源體上 如可能接觸到蒸汽的場所 使用本機 移動本機時 請緊握主機 移動時若握前面板 會導致前面板脫落 從而摔落主機 造成身體損傷 請勿在沒有過濾網的情況下操作本機 請勿清洗活性碳過濾網和HEPA過濾網 這不僅不能增強過濾網的性能 反而可能會導致...

Page 21: ...可能會影響本機正常操作 請勿安裝在窗簾等可能會接觸到進氣口或排氣口的地方 否則該物會被污染或導致本機故障 請勿安裝在由於溫度劇烈變化而導致本機直接暴露於冷凝環境的地方 安裝位置必須穩固 且通風良好 請將本機安裝在牆壁 木柱 橫木等平坦且具足夠支撐力的地方 請勿將本機安裝在薄牆壁或石膏板上 若將其安裝在支撐性強度不大的牆上時 則可能會導致摔落情況發 生 如欲將本產品安裝在厚度小於10 毫米的木牆上時 請在安裝前與您的經銷商聯絡以確認牆壁的強度 移動本機時 請緊握主機 移動時若握著前面板 可能會導致前面板脫落 從而摔落主機 造成身體損傷 請勿安裝在會產生黑煙的地方 如廚房等 否則可能會導致本機表面破裂或感應器故障 過濾網指南 遵照說明書的指示 了解正確保養和清潔過濾網的方法 C 3 ...

Page 22: ...件 C 4 電源開 關按鈕 風扇控制按鈕 關機定時器按鈕 異味感應器 過濾網支架 HEPA過濾網 白色 備有微生物控制過濾網 藍色 活性碳過濾網 除臭過濾網 不銹鋼前過濾網 前面板 背部 電源線定位頁片 電源線 電源插頭 附件 遙控器 1 個 電池 2枚AA電池 使用說明書 牆壁安裝配套 掛牆托架 木螺絲釘 4枚 魚尾栓 4枚 排氣口 插頭形狀因國家 而異 離子簇指示燈 風速指示燈 關機定時器顯示指示燈 遙控接收器 ...

Page 23: ...池 使用2 枚A A 錳性電 池 當長時間不使用本機或遙控器時 請取出電池 這樣可防止遙控器由於電池 漏液而損壞 隨機附送的電池必須為初次使用 並且電量可能在1年內耗盡 安裝遙控器電池 1 1 1 1 1 打開後蓋 按下並滑動 以打開後蓋 2 2 2 2 2 裝入電池 依照圖示的正 負 極標記裝入電池 3 3 3 3 3 推回後蓋 準備工作 使用遙控器 對著主機接收器操作遙控器 由前面計 信號覆蓋範圍約為7米 確認沒有物體阻擋遙控器的信號 當接收到信號時 主機會發出 嗶 聲 注意 避免掉下或損壞遙控器 或是在過度潮濕 陽光直 接照射或靠近熱源的地方使用遙控器 接收器 發射器 ...

Page 24: ...6 安裝注意事項 在固定掛牆托架之前 應確認牆壁上不存在任何妨礙安裝的障礙物 然後用隨機提供的木螺絲釘通過螺絲釘孔 安裝掛牆托架 在牆上 木柱 石膏板上或類似之物上安裝裝置時 他們的表面應平坦 並且具足夠的強度 如果牆體強度較弱或由混凝土製成 則應由電子器材商店的專業人員進行安裝 避免安裝位置靠近反用換流器燈或陽光直射的位置 1 確定安裝位置 按下圖所示在支架周圍留出空間位置 支架周圍若空間大小不夠 則無法安裝本 裝置 如果您喜歡直立式安裝 請採 用另購支架FZ FC1TS 直立式安裝 掛牆托架的中心線 主機中心線 螺絲釘孔 60毫米 3毫米 330毫米 48毫米 16毫米 92毫米 54毫米 235毫米 207毫米 掛牆托架 電源線 337毫米 主機尺寸 482毫米 主機尺寸 螺絲釘孔 主機中心線 主機尺寸 距離側牆面70厘米 以上 45厘米以上 距離天花板 距離側牆面70厘米以上 ...

Page 25: ...板或灰泥面上安裝時 牆上鑽孔深度至少為35毫米 直徑至少為5毫米 推入魚尾栓 並用木螺絲釘固 定主機 在木柱 過梁或其他木製表面上安裝時 安裝時使用木螺絲釘 C 7 木柱 注意 若將本產品安裝於厚度少於10 毫米的木製牆壁上 請在安裝前與您的銷售商聯 繫以確認牆壁的強度 請將本機安裝在牆壁 木柱 過梁等平坦且支撐強度大的地方 安裝時確保裝置向上直立 無左 右傾斜 木製過梁 掛牆托架 牆壁的孔 魚尾栓 木螺絲釘 安裝在木柱上 安裝在木製過梁上 木螺絲釘 4枚 5毫米 35毫米 ...

Page 26: ...方 電源線定位頁片 電源線牽向裝置的右側 注意事項 注意事項 注意事項 注意事項 注意事項 為防止刮傷或損壞裝置 在將其安裝到牆壁上之前 請將其放在一塊軟布上 請勿將電源線與其他線纜一起牽入 也不要扭彎電源線 請勿改動電源線 注意不要損壞電源線 前面板 排氣口 1 2 電源線定位頁片 3 將本機安裝到牆壁上 1 將本機面向上放置 取下 前面板和過濾網支架 2 調整電源線的長度 1 量度裝置和牆上插座間的距離 參見第C 6頁 2 將本機面向下放置 將電源線插入電源 線定位頁片中 將電源線調整到所量度 的長度 過濾網支架 ...

Page 27: ...記 將裝置掛在掛牆托架上 滑動到正確 位置 定位正確後 輕輕向下移動本機 直至與支架嚙合 5 再次檢查安裝 請確定本機的爪鉤正確地被掛置 否則 裝置會傾側移動 此外 還可能會 導致本機摔落 造成損壞 確保電源線沒有被本機夾著 6 牆壁安裝托架 掛牆托架 如何取下本機 將電源插頭從牆壁電源插座上拔出 取下前面板和 過濾網支架 用手握住裝置的下角 輕輕向上抬 起 然後將其向左或向右滑動 然後向上抬離 1 2 2 2 1 標記 約8厘米 爪形槽 約8厘米 標記 爪形槽 與右側掛鉤孔對齊 與左側掛鉤孔對齊 ...

Page 28: ...袋中取出前過濾網 活性碳過濾網和HEPA過濾 網 3 將HEPA放在過濾網支架內 請勿將過濾網以相反方向安裝 否 則將影響本機正常操作 4 將活性碳過濾網放在HEPA過 濾網上面 活性碳過濾網無正反方向之分 5 下一步 將前過濾網放進過 濾網支架內 將前過濾網上的4個頁片按入到過濾 網支架上的孔中 C 10 安裝過濾網 前過濾網 活性碳過濾網 HEPA過濾網 過濾網支架 HEPA過濾網 過濾網支架 前過濾網 活性碳過濾網 HEPA過濾網 過濾網支架 頁片 如何取下不銹鋼前過濾網 活性碳過濾網 HEPA過濾網 頁片 ...

Page 29: ...中文 C 11 6 將過濾網支架裝進主機 7 在日期標籤上填寫開始使用 的日期 該日期將作為日後過濾網更換時間 的參考之用 8 將前面板裝進主機 9 將電源插座插入牆上的插座 內 並使用遙控器啟動或停 止操作 日期標籤 爪形槽 插爪 過濾網支架 前面板 ...

Page 30: ...掉電源線 否則主機啟動後將維持前一 次的操作模式 風扇控制按鈕 風扇速度可在靜音和最大兩種模式間進行轉換 關機定時器按鈕 每按一次該按鈕 設定時間將按以下順序設 定 選擇 4小時 定時 4小時 指示燈會點 亮 如果定時設置為1小時 則指示燈轉換至 1小時 C 12 將插頭插入牆壁插座後的頭30分鐘內 裝置將檢測空氣狀況 自動操作 異味感應器檢測空氣中雜質的含量 風速會根據檢測狀況自動被轉換 手動操作 不管空氣中雜質的含量 風速可根據需要在靜音 Silent 和最大 Max 兩種 模式下進行切換 1小時 4小時 取消 靜音 最大 自動 ...

Page 31: ...示燈和風速指示燈 自動 開 關 除非拔掉電源線 否則主機啟動後將維持前一次 的操作模式 自動 風速 按鈕 風速將根據室內空氣的污染程度自動轉換 手動 風速 按鈕 風速可以在靜音和最大之間轉換 關機定時器按鈕 每按一次該按鈕 設定時間將按以下順序設定 選擇 4小時 定時 4小時 指示燈會點 亮 如果定時設置為1小時 則指示燈轉換至 1小時 遙控器操作 離子簇模式操作 當本產品正在操作時 本機會持續釋放數量大致相等的正 負離子群 這對於減少某些 空氣中的霉菌十分有效 1小時 4小時 取消 靜音 最大 ...

Page 32: ... 以下的過濾網使用壽命和更換時間是以每天吸10支煙 且集塵 除臭效能比初次使用時減少一半來 計算 HEPA過濾網 打開後約12個月 活性碳過濾網 打開後約12個月 更換過濾網 1 關於更換時過濾網的安裝指南 請參 見第C 10 11頁 2 在日期標籤上填寫過濾網開始使用的 日期 更換用的過濾網 型號 FZ 28SEF HEPA過濾網 備有微生物控制過濾網 1 只 活性碳過濾網 1 只 請向您的經銷商咨詢購買更換用的過 濾網事宜 棄置過濾網 請根據當地法律規定來棄置已使用的過濾網 HEPA過濾網材料 過濾網 聚丙烯 支架 聚酯 微生物控制過濾網 聚丙烯 聚乙烯 活性碳過濾網材料 除臭劑 活性碳 框架 聚酯 網 60 聚丙烯 40 聚酯 前過濾網 前面板 活性碳過濾網 過濾網 備有微生物控制過濾網 過濾網支架 主機 日期標籤 不可沖洗 可清洗 ...

Page 33: ...過濾網表面 如果髒的很厲害 將其從過濾網支架中取出清洗 注意 如要進行清洗 請使用一個軟刷 以及冷 溫水 金屬刷或硬刷可能會損壞過濾 網 清洗後將其放在陰涼處風乾 然 後將其放回過濾網支架內 規格 前過濾網 關於減少備用耗電量 當電源插頭插進插座時 本機在備用情況下所耗的電量為1 0瓦 若需節省用電 請在不使用本機時拔掉電源插頭 適用面積是指以最大風速操作本機的面積計算 適用面積表示該空間內所含的灰塵粒子可以在30分鐘內消除 異味感應器 型號 FU 28H A 電源 220V 50Hz 風速操作 風速調整 最大 靜音 29瓦 3 1瓦 額定功率 168立方米 小時 30立方米 小時 送風速度 適用面積 21平方米 電源線長度 2 5米 尺寸 482毫米 寬 x142毫米 深 x337毫米 高 482毫米 寬 x228毫米 深 x373毫米 高 標準安裝 6 2公斤 重量 ...

Page 34: ...主機發出喀嚓 滴答聲 當本機釋放離子時會發出滴答聲 此屬正常情況 而非故 障 排出的空氣有異味 檢查過濾網是否已經很髒 更換過濾網 參見C 14頁 離子簇空氣清新機釋放少量臭氧 這可能會產生異味 臭 氧量釋放量低於IEC 60335 2 65規定的安全標準 本機是否安裝在感應器難以感測到煙霧的地方 異味感應器是否被堵塞 如果是 請清潔開口處 參見第C 15頁 即使空氣中有煙霧時 主機也不操 作 C 16 錯誤顯示 指示燈 補救措施 靜音 風速指示燈閃爍 風扇馬達切斷或異常 操作停止 按開 關按鈕將重設錯誤顯示 但是若再次出現錯誤 請聯 絡您購買本機的商店 另購支架 型號 FZ FC1TS 請與您購買產品的銷售商聯繫購買支架 可提供選裝支架FZ FC1TS 用於把本機裝設在 地面或桌上 ...

Page 35: ...中文 ...

Page 36: ...SHARP CORPORATION Printed in Japan TINS A140KKRZ 04KK ...