E-4
POWER SOURCE
■
AC power
Check the setting of the AC voltage selector located on the
rear panel before plugging the unit into an AC socket. If neces-
sary, adjust the selector to correspond to the AC power volt-
age used in your area.
Selector adjustment:
Slide the selector with a screwdriver to the appropriate volt-
age number (AC 110 - 127 V or AC 220 - 240 V).
Notes:
●
If the unit will not be used for a long period of time, remove
the AC power lead from the AC socket.
●
Connection of the AC power lead to the unit disconnects
the batteries.
●
Never use a power lead other than the one supplied. Use
of a power lead other than the one supplied may cause an
electric shock or fire.
●
If a humming noise occurs, turn the power plug upside down
where it is connected to the AC power input socket on the
unit.
●
AC Plug Adaptor
In areas (or countries) where an AC socket as shown in illus-
tration
➁
is used, connect the unit using the AC plug adaptor
supplied with the unit, as illustrated. The AC plug adaptor is
not included in areas where the AC wall socket and AC power
plug can be directly connected (see illustration
➀
).
Note for users in Australia and New Zealand:
An AC plug adaptor is not supplied if the lead has an Austra-
lian Standard plug.
■
Battery power
1
Disconnect the AC power lead, and remove the battery com-
partment cover.
●
Connection of the AC power lead to the unit disconnects
the batteries.
2
Insert 10 “D” size batteries (UM/SUM-1, R20, HP-2 or simi-
lar) into the battery compartment.
●
When inserting or removing the batteries
➄
and
➉
, push
them towards the
ë
battery terminals.
●
Installing the batteries incorrectly may cause the unit to mal-
function.
●
Batteries are not included.
3
Replace the battery compartment cover.
Precautions for battery use:
●
Insert the batteries according to the direction indicated on
the rear panel.
●
Remove the batteries if they are weak or if the unit will not
be used for long periods of time. This will prevent potential
damage due to battery leakage.
●
Replace all old batteries with new ones at the same time.
●
Do not mix old and new batteries.
Caution:
Do not use rechargeable batteries (nickel-cadmium battery,
etc.).
Battery replacement:
Replace the batteries when they become weak and/or record-
ing or playback is impaired. This may occur even though radio
broadcasts are audible.
1
4
3
5
2
10
9
8
6
7
AC 220V
-240V
AC 110V
-127V
VOLTAGE
SELECTOR
AC 220V
-240V
AC 110V
-127V
VOLTAGE
SELECTOR
1
2
To AC INPUT
AC 110-127/220-240 V,
50/60 Hz
To an AC socket