IM-DR580H
– 13 –
[1] Measurement, calculation and setting procedure.
1
Set the TEST mode.
2
Activate the “Temp” menu in the “EEPROM” mode.
• In the test mode stop state, press the MENU button,
SKIP-DOWN button (three times), and PLAY button
(twice) in this order.
• “TM$$%%” appears. ($$ = temperature code, %% =
temperature reference value)
3
“TPin##” will appear when pressing the SKIP-UP button
once. (## = TEMP input AD value)
4
Calculate the temperature correction value by referring
to the ambient temperature and the “Temperature
measurement value correction table”.
5
Calculate the temperature reference value according to
the formula below.
• Temperature reference value = Microcomputer TEMP input
AD value + Temperature correction value
6
Press the SKIP-DOWN button once to display “TM$$%%”.
Press the VOLUME –/+ button to set “%%” to the value
calculated in step
5
.
7
Check if the temperature code ($$) is the same as in the
“Temperature measurement value correction table”
Ambient
temperature
Temperature
correction
+ 8
o
C ~ +10
o
C
- 05 h
+ 8.5
o
C
+11
o
C ~ +13
o
C
- 04 h
+ 11.6
o
C
+14
o
C ~ +16
o
C
- 03 h
+ 14.6
o
C
+17
o
C ~ +19
o
C
- 02 h
+ 17.6
o
C
+20
o
C ~ +22
o
C
- 01 h
+ 20.6
o
C
+23
o
C ~ +25
o
C
±
00 h
+ 23.6
o
C
+26
o
C ~ +28
o
C
+ 01 h
+ 26.6
o
C
+29
o
C ~ +31
o
C
+ 02 h
+ 29.6
o
C
+32
o
C ~ +34
o
C
+ 03 h
+ 32.6
o
C
Center
temperature
Ambient
temperature
Temperature
correction
Center
temperature
- 8
o
C ~ +10
o
C
08 h
+ 0.5
o
C
+ 3
o
C ~ +21
o
C
07 h
+ 12.0
o
C
+14
o
C ~ +33
o
C
06 h
+ 23.6
o
C
+26
o
C ~ +44
o
C
05 h
+ 35.0
o
C
[2] Temperature measurement value correction table.
Temperature reference setting method.
[3] Temperature code identification.
13 h : Adjustment servo retraction excessive retrial
16 h : C. IN detection time-over
17 h : A, B, E, F, and TCRSO offset measurement value out of
tolerable range
21 h : Focus retraction completion allowable time-over
22 h : Unable to activate the spindle motor
23 h : Track search completion allowable time-over
32 h : P-TOC read failure
42 h : U-TOC read failure
44 h : U-TOC write data write disabled/read check error
45 h : U-TOC write test failure
52 h : SD write data write disabled
72 h : EEPROM data read check sum error
73 h : Record head drive disabled (by EJECT lever)
82 h : Power overvoltage detection
83 h : The temperature sensor output error
91 h : Ambient temperature is higher that the allowable temperature
Explanation of error history code
Can't READ (*)
* =
f :
Focus pulled
a :
Servo adjustment
s :
Track search
r :
TOC information reading
p :
Spindle start
Er-MD (**)
** = 80
“Er-MD 80” appears when EEPROM data cannot be read correctly
(inconsistency of data and the checksum results).
EEPROM or communication paths including the microcomputer
may be defective.
When you change EEPROM, reset data by referring to the service
manual.
** = 41
“Er-MD41” appears when writing U-TOC fails. (Only recorders)
(Reading of the written data reveals errors.)
The record head, the recording signal generator circuit including
system LSI or the pickup laser may be defective.
TOC FORM (*)
* = t_ : TNO information
a_: Address information
Ln: Pointer information
(n = 0, 1, 2 or 4: UTOC sector number)
Error messages
Summary of Contents for IM-DR580H(BK)
Page 62: ...IM DR580H 62 M E M O ...