AR-5316 ADJUSTMENT 6-3
9) Measure the distance H between the paper lead edge and the image
print start position. Set the image print start position set value
(Exposure display <<AUTO+MAIN CASSETTE LAMP>> ON) again.
•1 step of the set value corresponds to about 0.1mm shift.
•Calculate the set value from the formula below.
H/0.1(mm) = Image print start position set value
<H: Print start position measurement value (mm)>
Example:
5/0.1 = 50 = about 50
Note: If the set value is not obtained from the above formula, perform the
fine adjustment.
10) Set the lead edge void adjustment value (Exposure display
<<TEXT>> ON)* again.
•1 step of the set value corresponds to about 0.1mm shift.
•Calculate the set value from the formula below.
B/0.05 (mm) = Lead edge void adjustment value
<B: Lead edge void (mm)>
Example:
When setting the lead edge void to 2.5mm
:2.5 /0.05 = about 50
Note: If the set value is not obtained from the above formula, perform the
fine adjustment.
*
Multi bypass tray lead edge void adjustment: Exposure display
<<TEXT + PHOTO>>
<Adjustment specification>
b.SPF image lead edge position adjustment (SIM50-6)
1) Set a scale on the OC table as shown below.
Note: Since the printed copy is used as a test chart, put the scale in
paralled with the edge lines.
2) Make a copy, Then use the copy output as an original to make an
SPF copy again.
3) Check the copy output. If necessary, perform the following
adjustment procedures.
4) Execute SIM 50-6.
5) Set the SPF lead edge position set value (Exposure display
<<AUTO>> ON) so that the same image is obtained as that obtained
in the previous OC image lead edge position adjustment.
<Adjustment specification>
Adjustment
mode
SIM
LED
Set
value
Spec
value
Set
range
OC image lead
edge position
SIM
50-1
PHOTO
R/0.1
Lead edge
void:
1 - 4mm
Image loss:
3mm or
less
1 ~ 99
Main cassette
print start
position
AUTO
+
MAIN
B/0.1
Multi bypass
tray print start
position
AUTO
+
MULTI
Lead edge void
TEXT
B/0.05
5
10
0mm
0mm
*
Fit the print edge with the paper edge, and perform the
lead edge adjustment.
5
10
2.5mm
2.5mm
Adjustment mode
SIM
LED
Set value Spec value
Set
range
SPF image lead
edge position
(1st print surface)
SIM
50-6
AUTO
1 step:
0.1mm shift
Lead edge
void:
1 - 4mm
Image loss:
3mm or
less
1 ~ 99
[06]ADJUSTMENT.fm 3 ページ 2005年7月1日 金曜日 午後5時27分