AR-5316 SIMULATIONS 7-3
06
02
Resist roller solenoid operation
check
When the [START] key is pressed in the sub code input state, the resist solenoid (RRS) turns ON for
500ms and OFF for 500ms. This operation is repeated 20 times.
After completion of the process, the machine goes into the sub code input standby mode.
When [INTERRUPT] key is pressed during the process, the machine goes into the sub code input
standby mode. When [CA] key is pressed, the simulation is terminated.
10
Cassette semi-circular roller
cleaning
First of all, remove the developer unit.
Enter the simulation code, specify the cassette to be cleaned with the tray select key, and press
START button. The main motor rotates to move the cassette semi-circular roller by half circle and
make the roller face downward.
After completion of cleaning, when INTERRUPT key is pressed, the machine goes into the sub code
entry standby mode and the roller returns to the original positions.
To clean another roller continuously, press INTERRUPT key to return the roller to the original
position, and execute the simulation again.
During the operation, the sub code is displayed on the display.
*
When CA key is pressed, the simulation mode is terminated.
However, the roller returns to the original position by the initial operation.
08
01
Developing bias output
When the [START] key is pressed, the developing bias signal is turned ON for 30 sec.
However, to calculate the actual output value is calculated, execute SIM25-01.
After completion of the process, the machine goes into the sub code input standby mode.
When [INTERRUPT] key is pressed during the process, the machine goes into the sub code input
standby mode. When [CA] key is pressed, the simulation is terminated.
02
Main charger output (Grid = HIGH) When the [START] key is pressed, the main charger output is supplied for 30 sec in the grid voltage
HIGH mode. After completion of the process, the machine goes into the sub code input standby
mode.
When [INTERRUPT] key is pressed during the process, the machine goes into the sub code input
standby mode. When [CA] key is pressed, the simulation is terminated.
03
Main charger output (Grid = LOW) When the [START] key is pressed, the main charger output is supplied for 30 sec in the grid voltage
LOW mode. After completion of the process, the machine goes into the sub code input standby
mode.
When [INTERRUPT] key is pressed during the process, the machine goes into the sub code input
standby mode. When [CA] key is pressed, the simulation is terminated.
06
Transfer charger output
Select an output mode with the [Mode select] key and press the [START] key. The transfer charger
output is delivered for 30 sec in the selected mode.
After 30 sec of transfer charger output, the machine goes into the sub code entry standby mode.
When [INTERRUPT] key is pressed during the process, the machine goes into the sub code input
standby mode. When [CA] key is pressed, the simulation is terminated.
21
1
Maintenance cycle setting
The current set maintenance cycle code is displayed (initial display), and the set data are stored.
22
01
Maintenance counter display
The maintenance counter value is displayed. (Alternate display by 3 digits)
04
Jam total counter display
The jam total counter value is displayed. (Alternate display by 3 digits)
05
Total counter display
The total counter value is displayed. (Alternate display by 3 digits)
08
SPF counter display
The SPF counter value is displayed. (Alternate display by 3 digits)
13
CRUM destination display
When this simulation is executed, the CRUM destination set (written) in the CRUM chip is displayed.
If the display does not match the destination code saved in the CRUM chip, it is judged as an error.
*This simulation is valid only for the models where the CRUM is valid.
Main
code
Sub
code
Contents
Details of operation
•Small size is Letter R (A4R) or smaller.
Display lamp
Output mode
AE mode lamp
AE mode lamp & PHOTO mode lamp
AE & TEXT & PHOTO mode lamp
Normal size width: Front surface
Small size width: Front surface
Manual paper feed mode
Code
Setting
0
1
150,000 sheets * Default
Free (999,999 sheets)
7-seg display
Meaning (CRUM destination)
7-seg display
Meaning (CRUM destination)
00
01
02
03
Not set yet
BTA-A
BTA-B
BTA-C
04
12
11
BTA-E
AL series
AR-5316(for SEC)