AR-5316 SIMULATIONS 7-6
49
12
Standby mode fusing fan RPM
setting
When this simulation is executed, the currently set code number is displayed.
When [MODE SELECT] key is pressed, the normal setting and the high fusing temperature setting
are switched alternatively.
Enter the code number and press START key, and the number is written into the EEPROM and the
machine goes into the sub code entry standby mode.
51
02
Resist amount adjustment
Used to adjust the contact pressure of the machine resist roller and the SPF resist roller onto the
paper.
(Operating procedure)
When this simulation is executed, the current set value is displayed.
When the exposure mode key is pressed, the following set items are changed sequentially. Enter an
adjustment value with the 10-key and press the [START] key, and the entered value will be saved and
a copy will be made. (Adjustment range: 1 ~ 99, Default: 50)
When the [CA] key is pressed, the entered value is saved and the simulation is terminated.
Supported for the installed models only. Skipped for the models without installation.
53
10
SPF scan position change-over
setting
Used to change over the scan position depending on that the SPF unit and the SPF document glass
holder section are of anti-dirt glass or not.
When this simulation is executed, the currently set code number is displayed.
Enter the code number corresponding to the SPF unit to be used and press [START] key, and the
setting will be changed over.
Though this setting is changed, the other set values are not affected. (The other set values remain
unchanged.)
When replacing and installing the SPF unit, it is recommendable to use this simulation to set the
scan position and execute the scan position automatic adjustment.
64
01
Self print
The optical system status is ignored and a self print is made. Also when a print command is sent
from the host, printing is performed.
(Operating procedure)
When this simulation is executed, warm-up is performed and the ready lamp is lighted.
(However, the scanner is invalid and no initial operation is made.)
Enter the code number with the 10-key, and select a cassette with the cassette select key and press
the [START] key. The selected cassette start paper feed and printing is performed in the selected
pattern.
*
Only the tray lamp and the online lamp are lighted, and no other lamps are lighted.
Printing is made in 1 by 2 mode, where one line is printed and the following two liens are not printed,
or in the grid pattern.
*
Input disable for 4 ~ 99
*
Print data are made on A3(11” x 17”) size. (A3(11” x 17”) paper is preferable.)
Main
code
Sub
code
Contents
Details of operation
Display lamp
Setting mode
Default
AE mode lamp
Normal temperature control (190°C or less)
Low speed rotation
TEXT mode
Fusing temperature of 190°C or above
High speed rotation
Code number
Setting
0
1
Low speed rotation
High speed rotation
Lighting lamp
Adjustment mode
AE, Main cassette lamp
AE, Manual paper feed lamp
AE, TEXT, PHOTO lamps
Main cassette paper feed
Manual paper feed
SPF document feed
Code No.
Mode
0
Set to the scan position of the current mass production SPF unit. (Default)
1
Set to the scan position of the ant-dirt SPF unit.
Code number
Pattern
0
1
2
3
1 by 2
Grid pattern
White paper
Black background