5
KB-3425LS/K/W
KB-4425LS/K/W
MICROWAVE MEASUREMENT PROCEDURE
A. Requirements:
) Microwave leakage limit (Power density limit): The power density of microwave radiation emitted by a microwave
oven should not exceed mW/cm
2
at any point 5cm or more from the external surface of the oven, measured prior to
acquisition by a purchaser, and thereafter (through the useful life of the oven), 5 mW/cm
2
at any point 5cm or more
from the external surface of the oven.
2) Safety interlock switches:
Primary interlock relay switch shall prevent microwave radiation emission in excess of the requirement as above
mentioned. Secondary interlock relay and door sensing switch shall prevent microwave radiation emission in excess
of
5 mW/cm2 at any point 5cm or more from the external surface of the oven.
B. Preparation for testing:
Before beginning the actual measurement of leakage, proceed as follows:
) Make sure that the actual instrument is operating normally as specified in its instruction booklet.
Important:
Survey instruments that comply with the requirement for instrumentation as prescribed by the performance standard for
microwave ovens, 2 CFR 030.0(c)(3)(i), must be used for testing.
2) Place the load of 275±5 ml (9.8 oz) of tap water initially at 20±5
O
C (68
O
F) in the center of the oven cavity.
The water container shall be a low form of 600 ml (20 oz) beaker with an inside diameter of approx. 8.5 cm (3-/2 in.)
and made of an electrically nonconductive material such as glass or plastic.
The placing of this standard load in the oven is important not only to protect the oven, but also to insure that any leakage
is measured accurately.
3) Set the cooking control on Full Power Cooking Mode.
4) Close the drawer and select a cook cycle of several minutes. If the water begins to boil before the survey is completed,
replace it with 275 ml of cool water.
C. Leakage test:
Closed-drawer leakage test (microwave measurement):
) Grasp the probe of the survey instrument and hold it perpendicular to the gap between the drawer and the body of the
oven.
2) Move the probe slowly, not faster than in./sec. (2.5 cm/sec.) along the gap, watching for the maximum indication on
the meter.
3) Check for leakage at the drawer screen, sheet metal seams and other accessible positions where the continuity of the
metal has been breached (eg., around the switches, indicator, and vents).
While testing for leakage around the drawer, pull the drawer away from the front of the oven as far as is permitted by
the closed latch assembly.
4) Measure carefully at the point of highest leakage and make sure that the highest leakage is no greater than 4mW/cm
2
,
and that the primary interlock switch/secondary interlock relay does turn the oven OFF before any door movement.
Summary of Contents for Insight KB-4425LK
Page 6: ... KB 3425LS K W KB 4425LS K W NOTES ...
Page 13: ...13 KB 3425LS K W KB 4425LS K W KB 3425LS ...
Page 35: ...35 KB 3425LS K W KB 4425LS K W IC 7 IC 8 OVEN TEMPERATURE SELF CLEANING CONTROL CIRCUIT ...
Page 36: ...36 KB 3425LS K W KB 4425LS K W OVEN DOOR LOCK MOTOR CONTROL CIRCUIT ...
Page 37: ...37 KB 3425LS K W KB 4425LS K W OVEN DOOR LOCK MOTOR DETECTION CIRCUIT ...