11-2
Existence Inspection by Point Measurement
11
To the next page
Select the point condition to be set.
1. Select a mode.(When the "AVG-
GRAYS" (average density) is selected
-
See below.)
2. Select a binary processing method.
-
page 3-9
3. Enter the threshold.
-
page 3-8
4. Select the point condition registers you
want to set.
When CALC RESULT (see page 15-8) is
set to "YES," circles are displayed for the
selected registers.
You can change the register number ranges (0 to
255 in the BINARY mode and 0 to 127 in the AVG-
GRAYS mode) using the up and down keys.
1. Select "(MEAS-COND)."
When "MEASUREMENT 1" is selected.
Æ
Setting (display) in AVG-GRAYS mode
1
MODE BINARY AVG-GRAYS
2
AVG-GRAY PROC
REGISTER NO.
4
POINT CONDITIONS
NUMERIC CALC
FIXED GRAY-ADJ
(VAR-DIFF VAR-RATE)
000 001 002 003 004 005 006 007
○ ○ ○ ○ ○ × × ×
○ ○ × × × × × ×
1. Select a mode.
2. Select an average light level
processing method.
3. Select the registers whose point
conditions you want to set.
COMPARE IMGS
-
Pages 3-23 to 3-25
-
Page 3-14
-
Page 3-10
Setting the measurement programs (pages 1-10 to 1-11: Select "POINT-MEAS" (point measurement)
on the "MEAS SELECTION" line, and press the SET key.)
[TYPE MEAS COND]
[MEASUREMENT1]
6
MEASUREMENT 1 POINT-MEAS C1 (MEAS-COND)
OPS-MENU RETURN LOCK
[TYPE MEAS COND]
6
MEASUREMENT 1
POINT-MEAS C1 (MEAS-COND)
1
MEAS SELECTION
NO POSI-DEVIATION CHK-DEG-MATCH
INSPECT-LEAD INSPECT-BGA/CSP
MEAS-BIN-AREA CNT-BIN-OBJ LABEL-BIN-OBJ
POINT-MEAS MULTI-POSI MULTI-MATCHES
2
SELECT CAMERA
CAM1 CAM 2 CAMPARE-IMGS(CAM1)
3
CHNG GRAY LEBEL
NO YES(00.0TIMES
γ
+
γ
- CHNG-L INCRS-M)
4
SPACE FILTER
NO
NUM-OF-TIMES 0(0~5)
[MEASUREMENT1]
①
MODE
BINARY AVG-GRAYS
②
BINARY PROCESS
FIXED THRESHOLD-ADJ(VAR-DIFF VAR-RATE)
③
THRESHOLD
U.LM255 L.LM100(0~255)
REGISTER NO.
④POINT CONDITIONS
NUMERIC CALC
OPS-MENU RETURU LOCK CHNG-REG EVALUATION NUM-CALC OUT-COND
000 001 002 003 004 005 006 007