19-4
Computer Link
19
*1 When the termination code is 08
(H)
(received an error response), the error code is contained in the
appended information. (Example: 0A
(H)
on a Sharp PC = parity error)
*2 Measurement number when outputting the results
00
(H)
= Measurement 0, Camera 1, 01
(H)
= Measurement 0, Camera 2, 02
(H)
= Measurement 1,
03
(H)
= Measurement 2, 04
(H)
= Measurement 3, 05
(H)
= Measurement 4
*3 Result output (Y0 to Y15)
*4 Measurement program for measurement 0
00
(H)
= none, 01
(H)
= positional deviation measurement
*5 Measurement programs for measurements 1 to 4
00
(H)
= none, 01
(H)
= positional deviation measurement, 02
(H)
= degree of match inspection, 03
(H)
=
lead inspection, 04
(H)
= BGA/CSP inspection, 05
(H)
= area measurement by binary conversion,
06
(H)
= object counting by binary conversion, 07
(H)
= object identification by binary conversion, 08
(H)
= point measurement, 09
(H)
= Multiple position measurement, 0A
(H)
= Multiple degree of match
inspections
*6 Output data from measurements 0 to 4 (block 0)
The data output will vary according to whether "ANY" or "BLOCK-ASSIGN" was selected on the
SERIAL OUTPUT item.
-
Pages 17-21 to 17-24
Ë
When a block is specified
- The measurement data from measurement numbers 0 to 4 in block 0 is output. (Max. 496
bytes).
- Measurement numbers that have not been specified will not output any data. (The space will be
filled by the next item. Max. 500 bytes.)
- See pages 19-6 to 19-14, for details about the measurement data in block 0.
Ë
When "ANY" is selected for the output
-
See page 19-17.
*7 Assigned block data
When the SERIAL OUTPUT item is set to "BLOCK-ASSIGN," the IV-S30 wil output the
measurement result data in the specified block number. When the SERIAL OUTPUT item is set
to "ANY," the nature of the output will depend on the output settings.
- For details about how to specify measurement output, see pages 17-21 and 17-22.
- No data is output if block 0 (00) is specified.
- For details about the measurement data block, see pages 19-5 to 19-16.
- The top address where the specified block of data is written will be an address made by
adding 512 bytes to the top address for writing results.
7
Bit
6
5
4
H (09005)
3
2
1
0
Y15 Y14 Y13 Y12 Y11 Y10 Y9 Y8
7
6
5
4
L (09004)
3
2
1
0
Y7 Y6 Y5 Y4 Y3 Y2 Y1 Y0
09000
09001
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
D0000
DM0000
D0256
DM0256
19000
19001
L
H
L
H
L
H
L
H
Termination code
Appended information
Output data from measurement 4 (block 0)
L
H
L
H
Assigned block data
Sharp
Mitsubishi
OMRON
Contents
Top address for
writing results
Top address for
writing results
+ 512 bytes