Setting Measurement Conditions
3-34
3
[3] Copying
When there are many common parameters between object types, it is most efficient to access those
existing sets of parameters in order to copy and then modify them.
The parameters of a previously specified object type are copied into another object type, after which
they can be modified.
Ë
Ë
Ë
Ë
Ë
Operation procedure
1. Select item "
1
OBJECT TYPE NO.," using the up and down keys and press SET key.
2. Using the left and right keys, enter the object type number (IV-S33M: 0 to 63, IV-S32M: 0 to 31,
IV-S31M: 0 to 15) for the target of the copy. Then, move the cursor to "YES" and press SET key.
3. Select item "SYSTEM," using the up/down and left/right keys and press the SET key.
-
The "OBJECT TYPE SYS." menu will be displayed on the lower window.
4. Move the cursor to "
5
COPY" using the up and down keys and press the SET key.
5. Enter the object type number for the source of the copy using the up and down keys. Then, press
the SET key.
-
The system will start copying.
Notes
- Do not disconnect the power while the IV-S30 is copying.
- Once data has been corrupted it will be necessary to start after initializing the setting, all over
again. Unless this is done it will not be possible to restart the machine.
- The reference images used for the gray scale seach function are not copied with the
operation above. Make sure reset them.
The measurement conditions of
the source object type. (The data
is copied from flash memory)
The measurement conditions of the target
object type. (The data is used to simplify
setting the target object's parameters)
The source of the copy
The target of the copy
On the MAIN OPS MENU, move the cursor to "MEA-CND" item, and press the SET key.
1
4
5
3
2
[TYPE MEAS COND]
[OBJECT TYPE SYS.]
1
OBJECT TYPE NO.
00(0~63) NO YES
OPS-MENU SAVE LOCK TITLE FINAL-CALC FINAL-OUTPUT I/O SYSTEM
OPS-MENU RETURN LOCK
1
REGST NG IMG NO YES
2
HALT ON NG MEAS NO YES
3
MNTR LIGHT LVL CAM1(1~2)NO YES
4
LIGHT LVL COND (TO NEXT SUB-MENU)
5
COPY
( TYPE00) EXEC
6
INITIALIZATION EXEC
7
MOVE ALL WINDOW (TO NEXT SUB-MENU)
Displayed when the
IV-S32M/S33M is
used.