LC-42D65U
5 – 13
8. Adjustment of white balance
8.1. White balance adjustment
Adjustment item
Adjustment conditions
Adjustment procedure
1
Setting
For detailed adjustment procedure, refer to “Kameyama Model Integral Monitor WB
Adjustment Specifications V1.6”.
1) Make the following settings for the set.
AV MODE: [DYNAMIC]
Backlight: +16
Active Backlight: OFF
Aging time: Min. 60 minutes
2) Connect the white balance adjustment tool to the set.
2
Automatic adjust-
ment execution
[Command]
Process mode
KRSW0001
KKT10037
Setting
KYOF0000
OSDS0001
SBSL0016
Multi-point adjustment
mode
MSET0001
Point 6
WBI60928
MG6G****
MG6B****
MG6R****
Point 5
WBI50764
MG5G****
MG5B****
MG5R****
[Adjustment procedure]
1) Using the remote controller, transmit the “monitor adjustment process” code.
2) Set the 6th point to the specified gradation level. With the strongest color being fixed,
turn down the R, G and B settings to their reference levels.
3) Set the 5th point to the specified gradation level. Correct the G setting (764 x 6th-
point G setting / 928) (rounded off), and make the R and B settings to their reference
levels.
4) Set the 4th point to the specified gradation level. Correct the G setting (652 x 6th-
point G setting / 928) (rounded off), and make the R and B settings to their reference
levels.
5) Set the 3rd point to the specified gradation level. Correct the G setting (428 x 6th-
point G setting / 928) (rounded off), and make the R and B settings to their reference
levels.
6) Set the 2nd point to the specified gradation level. Correct the G setting (348 x 6th-
point G setting / 928) (rounded off), and make the R and B settings to their reference
levels.
7) Set the 1st point to the specified gradation level. Correct the G setting (192 x 6th-
point G setting / 928) (rounded off), and make the R and B settings to their reference
levels.
8) With the MSET0003 command, write the adjustment values and turn off the AC
power.
* Initial R, G and B settings at point 6: Gradation level set at 928
* Initial R, G and B settings at points 1 thru 5: Corrected G setting at each point
(This is because the adjustment is made to achieve the same remainder of RGB setting /
4 at each point.)
[Adjustment value]
•
As per the “standard set” submitted by Engineering Department Teaching set
[Adjustment reference] Instrument: Minolta CA-210 Engineering instrument
Point 4
Level
Reference
Adj. spec
Ins. spec
WBI40652
Point 6
928
X=0.272
±
0.0025
±
0.0050
MG4G****
y=0.277
MG4B****
Point 5
764
X=0.272
±
0.0025
±
0.0050
MG4R****
y=0.277
Point 4
652
X=0.272
±
0.0035
±
0.0070
Point 3
y=0.277
WBI30428
Point 3
428
X=0.272
±
0.0050
±
0.0100
MG3G****
y=0.277
MG3B****
Point 2
348
X=0.272
±
0.0080
±
0.0150
MG3R****
y=0.277
Point 1
192
X=0.272
±
0.0110
±
0.0200
y=0.277
Point 2
WBI20348
MG2G****
MG2B****
MG2R****
Note
Set conditions for inspection
AV MODE: [DYNAMIC] (Reset)
Monochro: ON
Active Contrast: OFF
Aging Time: Min. 60 minutes
Point 1
WBI10192
MG1G****
MG1B****
MG1R****
Writing
MSET0003