LCY01023−6
【
Note 6-7
】
available area
7)Timing Characteristics of input signals
Timing diagrams of input signal are shown in Fig.3
7-1) Timing characteristics
Table 7-1
Parameter
Symbol
MIN
TYP
MAX Unit
Remarks
Clock Frequency
1/Tc
−
25.18 27.6
MHz
High time
Tch
5
−
−
ns
Low time
Tcl
10
−
−
ns
Duty ratio
Th/t
40
50
60
%
Data Setup
time
Tds
5
−
−
ns
Hold time
Tdh
10
−
−
ns
Horizontal sync.
Cycle
TH
30
31.78
−
μ
s
signal
770 800 900
clock
Pulse width
THp
2
96
200 clock
Vertical sync.
Cycle
TV
515
525
560
line
signal Pulse
width
TVp
2
96
200
line
Horizontal display period
THd
640
640
640
clock
Hsync-Clock phase difference
THc
10
−
Tc-10 ns
Hsync-Vsync phase difference
TVh
1
−
Tc-THp clock
Vertical display start position
TVs
103
103
103
Line
Vertical data period
TVd
350
350
350
Line
Note) In case of lower frequency, the deterioration of display quality, flicker etc., may be occurred.
7-2) Horizontal display position
①
In case ENAB is active
The horizontal display position is determined by ENAB signal. The input data corresponding to the 5
edge from rising of ENAB signal is displayed at the left end of the active area. (shown in Fig.3)
Parameter symbol
Min.
Typ.
Max.
Unit
Remark
Enable signal
Setup time
Tes
5
−
Tc
−
10
ns
Pulse width
Tep
2
640
640
clock
Hsync-Enable signal phase
Difference
THe 44
−
TH-644 clock
②
In case ENAB is “Low”
The display starts from the data of C108(clock) as shown in Fig.3.
Be careful that the module does not work when ENAB is Hi fixed.
7-3) Vertical display position
ENAB signal has no relation to the vertical display position.
50℃
25℃
‑30℃
Dimming
Temperature
Available area
3.5%
9.0%
80%
100%
sharp