MD-R2
– 14 –
• Test Mode
1. AUTO pre-adjustment mode
• Automatic pre-adjustment is performed. (After adjustment the grating adjustment mode is set.)
• The adjustment value is output with the aid of system controller interface.
2. AUTO adjustment mode
• Automatic adjustment is performed.
• The adjustment value is output with the aid of system controller interface.
• Continuous playback is performed. (Error rate indication, jump test)
3. RESULT sub-mode
• The measurement value, set value and calculated value are indicated.
• The set value is changed manually (in servo OFF state).
4. RESULT mode (final adjustment)
• The set value (after calculation) is indicated.
• The set value is changed manually (in servo OFF state).
5. MANUAL pre-adjustment mode
• RF side manual adjustment is performed.
• Focus and tracking signal ATT manual adjustment is performed.
• Focus and tracking signal offset setting is performed.
6. MANUAL adjustment mode
• Focus and tracking signal ATT manual adjustment is performed.
7. EEPROM setting mode
• Various coefficients of digital servo are changed manually.
• Each servo is set to ON individually.
• Temperature detection terminal voltage is measured, and the reference value is determined.
8. TEST-PLAY mode
• Continuous playback from the specified address is performed.
• C1 error rate measurement, ADIP error rate measurement.
9. TEST-REC mode
• Continuous recording from the specified address is performed.
• Change of record laser output (servo gain is also changed according to laser output)
10. INNER mode
• The position where the INNER switch is turned on is measured.
11. EJECT mode
• TEMP setting (of EEPROM setting)
• CONTROL setting (of EEPROM setting)
• Setting of laser power (record/playback power)
1. AUTO pre-adjustment mode (Low reflection disc only)
Step No.
Setting Method
Remarks
Display
Step 1
Testmode STOP state
[ t s m
e
]
Step 2
Press once the ENTER button.
AUTO pre-adjustment menu
[ A U T O ]
Step 3
Press once the MD PLAY button. The slide moves to the innermost periphery, and automatic
[
: _ _ _ _ _ _ ]
pre-adjustment is started.
• During automatic adjustment
changes as follows.
HAo
→
RFg
→
SAg
→
SBg
→
PTG
→
PCH
→
GTG
→
GCH
→
RCG
→
SEG
→
RFG
→
SAG
→
HAO
→
HEO
→
TCO
→
LAO
End of adjustment
If adjustment is OK, Step 4.
If adjustment is NG, Step 5.
Step 4
Grating adjustment,
[ _ C O M P L E T E _ ]
adjustment value output
Press once the MD STOP button. STEP 2
Step 5
Adjustment value output
[ C a n ' t _ A D J . ]
Press once the MD STOP button. STEP 2 AUTO pre-adjustment menu
•
: Adjustment name