– 17 –
MD-R2
• If the jog key upward/downward is pressed during setting indication, the setting increases/decreases, and the new setting is stored in RAM.
• If the REC button is pressed, the setting returns step by step excepting the following case.
A signal offset (HAO)
→
Offset tentative setting
→
RF side FG adjustment (RFG)
RF side TCRS adjustment (RCG)
→
RF side groove TG adjustment (GTG)
RF side groove TG adjustment (GTG)
→
Innermost periphery move
→
RF side pit section adjustment (PTG)
RF side pit TG adjustment (PTG)
→
RF side FG rough adjustment (RFg)
→
Laser lighting (LON)
Laser lighting (LON)
→
Offset "0" setting
→
A signal offset tentative measurement (HAo)
If the measurement value is within the OK range, " " appears on the 8th character.
Step 1
Testmode STOP state
[ t s m
e
]
Step 2
Press the ENTER button six times.
MANUAL adjustment menu
[ _ M N U _ A J S T _ ]
Step 3
Press once the MD PLAY button. Initial setting
→
Temperature measuring mode
[ T M P : _
_ _ _ ]
Step 4
Press once the ENTER button.
Laser ON
[ L O N : _ _ _ _ _ _ ]
Step 5
Press once the ENTER button.
Innermost periphery move
→
Tracking ATT (E signal) setting
[ P E G :
]
Step 6
Press once the ENTER button.
Tracking ATT (F signal) setting
[ P F G :
]
Step 7
Press once the ENTER button.
Indication of tracking EFMIO measurement
[ P M I :
_ _ _ ]
Step 8
Press once the ENTER button.
Focus ATT (A signal) setting
[ H A G :
]
Step 9
Press once the ENTER button.
Focus ATT (B signal) setting
[ H B G :
]
6. MANUAL adjustment mode
High reflection disc
Step No.
Setting Method
Remarks
Display
• If the MD STOP button is pressed while the MANUAL adjustment menu is displayed, the state is changed to the TEST mode STOP
state.
• If the REC button is pressed, the setting returns step.
Step 1
Testmode STOP state
[ t s m
e
]
Step 2
Press the ENTER button six times.
MANUAL adjustment menu
[ _ M N U _ A J S T _ ]
Step 3
Press once the MD PLAY button. Initial setting
→
Temperature measuring mode
[ T M P : _
_ _ _ ]
Step 4
Press once the ENTER button.
Laser ON
[ L O N : _ _ _ _ _ _ ]
Step 5
Press once the ENTER button.
Innermost periphery move
→
Tracking ATT (E signal) setting
[ P E G :
]
Step 6
Press once the ENTER button.
Tracking ATT (F signal) setting
[ P F G :
]
Step 7
Press once the ENTER button.
Indication of tracking EFMIO measurement (pit section)
[ P M I :
_ _ _ ]
Step 8
Press once the ENTER button.
Focus ATT (A signal) setting
[ L A g :
]
Step 9
Press once the ENTER button.
Focus ATT (B signal) setting
[ L B g :
]
Step 10
Press once the ENTER button.
Outside periphery move
→
Track closs setting
[ G C G :
]
Step 11
Press once the ENTER button.
Tracking ATT (E signal) setting
[ G E G :
]
Step 12
Press once the ENTER button.
Tracking ATT (F signal) setting
[ P F G :
]
Step 13
Press once the ENTER button.
Indication of tracking EFMIO measurement (groove section)
[ G M I :
_ _ _ ]
Step 14
Press once the ENTER button.
Focus ATT (A signal) setting
[ L A G :
]
Step 15
Press once the ENTER button.
Focus ATT (B signal) setting
[ L B G :
]
Low reflection disc
Step No.
Setting Method
Remarks
Display
• If the MD STOP button is pressed while the MANUAL adjustment menu is displayed, the state is changed to the TEST mode STOP
state.
• If the REC button is pressed, the setting returns step by step excepting the following case.
Track closs ATT setting (GTG)
→
Innermost periphery move
→
Focus ATT (B signal) setting (LBg)
Step 1
Testmode STOP state
[ t s m
e
]
Step 2
Press the ENTER button seventimes.
EEPROM setting menu
[E E P R O M _ S E T]
Step 3
Press once the MD PLAY button. Focus setting menu
[ _ _ F o c u s _ _ _ ]
Step 4
Press once the MD PLAY button. Focus system loop filter gain constant setting
[ F G _ _ _ _ _ _
]
Step 5
Press once the ENTER button.
Focus system loop filter f characteristic constant 1 setting
[ F F 1 _ _ _ _ _
]
Step 6
Press once the ENTER button.
Focus system loop filter f characteristic constant 2 setting
[ F F 2 _ _ _ _ _
]
Step 7
Press once the ENTER button.
FZC oscillation histerisis level setting a
[ F Z H L E V _ _
]
Step 8
Press once the ENTER button.
Comparison level setting (normal) in case of FOK generation
[ F O K L E V n _
]
7. EEPROM setting mode
a) Focus setting
Step No.
Setting Method
Remarks
Display