MD-R2
– 18 –
Step 9
Press once the ENTER button.
Comparison level setting in case of FOK generation
[ F O K L E V f _
]
(when focus is "ON")
Step 10
Press once the ENTER button.
LPF coefficient setting (normal) in case of FOK generation
[ F O K L P F n _
]
Step 11
Press once the ENTER button.
LPF coefficient setting in case of FOK generation
[ F O K L P F f _
]
(when focus is "ON")
Step 12
Press once the ENTER button.
Waiting time setting in case of auto-focus retraction
[ W A I T f_ _ _
]
Step No.
Setting Method
Remarks
Display
•
: Setting volue
• Pressing the REC button causes reversing.
• When the jog key is turned upward while the setting is displayed, the setting increases, and a new setting is stored in LSI.
• When the jog key is turned downward while the setting is displayed, the setting increases, and a new setting is stored in LSI.
Step 1
Testmode STOP state
[ t s m
e
]
Step 2
Press the ENTER button seven times.
EEPROM setting menu
[E E P R O M _ S E T]
Step 3
Press once the MD PLAY button. Focus setting menu
[ _ _ F o c u s _ _ _ ]
Step 4
Press once the ENTER button.
Spindle setting menu
[ _ S p i n d l e _ _ ]
Step 5
Press once the MD PLAY button. Spindle system loop filter gain constant setting
[ S P G _ _ _ _ _
]
(Until tracking servo ON)
Step 6
Press once the ENTER button.
Spindle system loop filter gain constant setting
[ S P G _ i n _ _
]
(After tracking servo ON, inner periphery)
Step 7
Press once the ENTER button.
Spindle system loop filter gain constant setting
[ S P G _ m i d _
]
(After tracking servo ON, center)
Step 8
Press once the ENTER button.
Spindle system loop filter gain constant setting
[ S P G _ o u t _
]
(After tracking servo ON, outside periphery)
Step 9
Press once the ENTER button.
Spindle system loop filter f characteristic constant 1 setting
[ S P 1 _ _ _ _ _
]
Step 10
Press once the ENTER button.
Spindle system loop filter f characteristic constant 2 setting
[ S P 2 _ _ _ _ _
]
Step 11
Press once the ENTER button.
Spindle system loop filter f characteristic constant 3 setting
[ S P 3 _ _ _ _ _
]
Step 12
Press once the ENTER button.
Spindle system loop filter f characteristic constant 4 setting
[ S P 4 _ _ _ _ _
]
Step 13
Press once the ENTER button.
Spindle system loop filter f characteristic constant 5 setting
[ S P 5 _ _ _ _ _
]
Step 14
Press once the ENTER button.
Spindle drive output limitter setting
[ S P D L I M _ _
]
b) Spindle setting
Step No.
Setting Method
Remarks
Display
•
: Setting volue
• Pressing the REC button causes reversing.
• When the jog key is turned upward while the setting is displayed, the setting increases, and a new setting is stored in LSI.
• When the jog key is turned downward while the setting is displayed, the setting increases, and a new setting is stored in LSI.
Step 1
Testmode STOP state
[ t s m
e
]
Step 2
Press the ENTER button seven times.
EEPROM setting menu
[E E P R O M _ S E T]
Step 3
Press once the MD PLAY button. Focus setting menu
[ _ _ F o c u s _ _ _ ]
Step 4
Press the ENTER button two times.
Tracking setting menu
[ _ T r a c k i n g _ ]
Step 5
Press once the MD PLAY button. Tracking system loop filter gain constant setting
[ T G _ _ _ _ _ _
]
Step 6
Press once the ENTER button.
Spindle system loop filter f characteristic constant 1 setting
[ T F 1 _ _ _ _ _
]
Step 7
Press once the ENTER button.
Spindle system loop filter f characteristic constant 2 setting
[ T F 2 _ _ _ _ _
]
Step 8
Press once the ENTER button.
Setting of tracking system servo mode 4
[ S V C N T 4 _ _
]
Step 9
Press once the ENTER button.
Tracking deceleration pulse level setting (for one line jump)
[ T R B L V 0 _ _
]
Step 10
Press once the ENTER button.
Tracking deceleration pulse level setting (for 10 line jump)
[ T R B L V t _ _
]
Step 11
Press once the ENTER button.
Tracking kick pulse level setting (for one line jump)
[ T R K L V 0 _ _
]
Step 12
Press once the ENTER button.
Tracking kick pulse level setting (for 10 line jump)
[ T R K L V t _ _
]
Step 13
Press once the ENTER button.
Tracking drive pulse width setting (for one line jump)
[ T D P W o _ _ _
]
Step 14
Press once the ENTER button.
Tracking drive pulse width setting (for 10 line jump)
[ T D P W t _ _ _
]
Step 15
Press once the ENTER button.
Tracking slip stop time setting (for one line jump)
[ S L C T 0 _ _ _
]
Step 16
Press once the ENTER button.
Tracking slip stop time setting (for 10 line jump)
[ S L C T t _ _ _
]
Step 17
Press once the ENTER button.
Tracking slip stop time setting (move)
[ S L C T m _ _
]
c) Tracking setting
Step No.
Setting Method
Remarks
Display