– 19 –
MD-R2
12.2 ~ 15.8
-3
15.9 ~ 19.6
-2
19.7 ~ 23.2
-1
23.2 ~ 26.8
0
26.9 ~ 30.7
+1
30.8 ~ 34.3
+2
34.4 ~ 37.9
+3
Step 18
Press once the ENTER button.
TCRS comparison level 1 for high reflection
[ T C R S C I P _
]
Step 19
Press once the ENTER button.
Comparison level in case of COUT generation (playback)
[ C O T L V p _ _
]
Step 20
Press once the ENTER button.
Comparison level in case of COUT generation (pecord)
[ C O T L V r _ _
]
Step 21
Press once the ENTER button.
Auto-move waiting time setting
[ W A I T m_ _ _
]
Step No.
Setting Method
Remarks
Display
d) Sled setting
Step 1
Testmode STOP state
[ t s m
e
]
Step 2
Press the ENTER button seven times.
EEPROM setting menu
[E E P R O M _ S E T]
Step 3
Press once the MD PLAY button. Focus setting menu
[ _ _ F o c u s _ _ _ ]
Step 4
Press the ENTER button three times.
Sled setting menu
[ _ _ _ S l e d _ _ _ ]
Step 5
Press once the MD PLAY button. Slide system loop filter gain constant setting
[ S L G _ _ _ _ _
]
Step 6
Press once the ENTER button.
Slide system loop filter f characteristic constant 2 setting
[ S L 2 _ _ _ _ _
]
Step 7
Press once the ENTER button.
Sled output limitter setting
[ S L D L I M _ _
]
Step 8
Press once the ENTER button.
Slide servo output dead zone level setting
[ S L D L E V _ _
]
Step 9
Press once the ENTER button.
Slide kick pulse level setting (forced move)
[ S L K L V k _ _
]
Step 10
Press once the ENTER button.
Slide kick pulse level setting (for 10 lines jump auxiliary use)
[ S L K L V t _ _
]
Step 11
Press once the ENTER button.
Slide kick pulse level setting (move)
[ S L K L V m _ _
]
Step No.
Setting Method
Remarks
Display
•
: Setting volue
• Pressing the REC button causes reversing.
• When the jog key is turned upward while the setting is displayed, the setting increases, and a new setting is stored in LSI.
• When the jog key is turned downward while the setting is displayed, the setting increases, and a new setting is stored in LSI.
•
: Setting volue
• Pressing the REC button causes reversing.
• When the jog key is turned upward while the setting is displayed, the setting increases, and a new setting is stored in LSI.
• When the jog key is turned downward while the setting is displayed, the setting increases, and a new setting is stored in LSI.
Data correction table
Ambient temperature (
°
C)
Temperature correction
EEPROM record value = Microcomputer measurement value +
Correction
*
EEPROM record value
Value to be measured by the microcomputer at +25
°
C
* Microcomputer measurement value
Value to be measured by the microcomputer at specific
temperature
* Correction value
Correction value for conversion to measurement value at
+25
°
C (see the table shown left)
TEMP • Input temperature correction.
• Correct the TEMP. data according to the PWB ambient temperature, and input it.
• Since the temperature rise causes error of temperature sensing part (RF IC), the following requirements must be observed.
1
Perform the TEST mode without mechanical connection.
2
This operation must be performed quickly after power is supplied.