MX-M200D SIMULATIONS 7-10
07
08
Shifting with warm-up display
Used to measure the warm-up time.
When this simulation is executed, the following warm-up window is displayed.
The time required for starting the warm-up and completing the initializing operation and shifting to the stand-
by state is displayed.
* Though [CA] key is pressed, the machine does not enter the aging mode of intermission 0 sec.
Press [CA] key to exit the simulation mode.
(The aging function is omitted from SIM 07-01.)
Note: Toner supply operation is not performed during this simulation.
08
01
Developing bias output
Used to check the developing bias output.
When this simulation is executed, the following execution start window is displayed.
When [OK] key or [START] key is pressed, the developing bias signal is turned ON for 30sec. When
measuring the actual output value, however, use SIM 25-01.
After completion of the process, the machine returns to the sub code input window.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Interrupts output operation and shifts to the sib code input window.
02
Main charger output (Grid = HIGH)
Used to check the main charger output.
When this simulation is executed, the following execution start window is displayed.
When [OK] key or [START] key is pressed, the main charger is turned on for 30 sec in the grid voltage HIGH
mode.
After completion of the process, the machine returns to the sub code input window.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Interrupts output operation and shifts to the sub code input window.
03
Main charger output (Grid = LOW)
Used to check the main charger output.
When this simulation is executed, the following execution start window is displayed.
When [OK] key or [START] key is pressed, the main charger is turned on for 30 sec in the grid voltage LOW
mode.
After completion of the process, the machine returns to the sub code input window.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Interrupts output operation and shifts to the sub code input window.
Main
code
Sub
code
Contents
Remark
Sim7-8 W-UP C-MODE
WARMING UP.
1
(Warming up window)
Sim7-8 W-UP C-MODE
WARM UP COMPLETED.
10
(Warming up completion window)
Sim8-1 DV BIAS
PRESS OK KEY
EXEC
Sim8-1 DV BIAS
EXEC
[OK] key or [START] Key
(Execution start window)
(Execution window)
Sim8-2 MHV(H)
PRESS OK KEY
EXEC
Sim8-2 MHV(H)
EXEC
[OK] key or [START] Key
(Execution start window)
(Execution window)
Sim8-3 MHV(L)
PRESS OK KEY
EXEC
Sim8-3 MHV(L)
EXEC
[OK] key or [START] Key
(Execution start window)
(Execution window)