MX-M200D SIMULATIONS 7-22
26
30
CE mark conformity control ON/OFF
Used to set Yes/No of CE mark conformity.
When this simulation is executed, the current set value is displayed. Enter a value with numeric keys and
press [OK] key or [START] key. The set value is saved to EEPROM and the machine returns to the sub code
input window.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
Default:
0: 100V series
1: 200V series
31
Auditor mode exclusive setup
Used to set whether paper feed is allowed from the manual paper feed tray of not when the auditor is set to
the coin vendor mode.
* When this setting is set to ON, if the auditor mode is the coin vendor mode and the standard tray setting is
set to the manual paper feed tray, the standard tray setting is set to the main tray.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
Default:
1
36
Cancel of stop at maintenance life over
"Stop" or "Cancel of stop" can be selected when the maintenance counter reaches the life over.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code entry menu.
Default:
1
37
Cancel of stop at developer life over
"Stop" or "Cancel of stop" can be selected when the developer counter reaches the life over..
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code entry menu.
Default:
1
38
Cancel of stop at drum life over
"Stop" or "Cancel of stop" can be selected when the drum counter reaches the life over.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code entry menu.
Default:
1
Main
code
Sub
code
Contents
Remark
Sim26-30 CE MARK
1:CE MARK CTRL
0=OFF
1=ON
[ 0-1]
Code: Setting
0 : CE mark support control OFF
1 : CE mark support control ON
0
0
Sim26-31 AUDITOR
1:AUDITOR
[ 0-2]
Code: Setting
0 : Exclusive setting OFF (Manual paper feed enable)
1 : Exclusive setting ON (Manual paper feed disable)
2 : Exclusive setting OFF (Manual paper feed enable) + A3/WLT charge
1
1
Sim26-36 MAINTESTOP
1:MAINTE OVER
[ 0-1]
Code: Setting
0 : Stop
1 : Cancel of stop
1
1
Code: Setting
0 : Stop
1 : Cancel of stop
Sim26-37 DEVE STOP
1:DEV LIFE OVER
[ 0 - 1]
1
1
Code: Setting
0 : Stop
1 : Cancel of stop
Sim26-37 DEVE STOP
1:DRM LIFE OVER
[ 0-1 ]
1
1