background image

SIM426-010

 

 

 

produce high voltage and current which could present an 
increased hazard and may cause serious injury or death. 

5. 

Do not connect the PV modules directly to the loads such 
as 

motor since the variation of the output power depending 

on the solar irradiation causes damage for the connected 

motor. 
1:  In  the  case  of  a  brushless  motor,  the  lock  function 
becomes  active  and  the  hall  IC  is  most  likely  to  be 
damaged.  

2: In the case of a brush type motor, the coil is most likely 

to be damaged. 

6. 

In case of snow build-up, snow would slide easier on the 
smooth surface of the module than other parts of the roof. 
Snow may suddenly slide, fall off the roof and  hit nearby 
objects/areas.  Take  preventive  measures  (e.g.  snow 
stopper) when there is possible risk such case would cause 
an injury or a damage. 

 

GENERAL SAFETY 

1. 

Consult local codes and other applicable laws concerning 
required  permits  on  regulations  for  installation  and 
inspection requirements. 

2. 

Before  installing  a  PV  module,  contact  appropriate 
authorities to determine permit, installation and inspection 
requirements that should be followed. 

3. 

Install PV modules and ground frames in accordance with 
applicable rules and regulations. 

4. 

PV  modules  should  be  installed  and  maintained  by 
qualified  personnel.  Only  installer/servicer  personnel 
should have access to the PV module installation site. 

5. 

No matter where the PV modules are installed, either roof 
mounted construction or any other type of structures above 
the ground, appropriate safety practices should be followed 
and required safety equipment should be used in order to 
avoid possible safety hazards. Note that the installation of 
some  PV  modules  on  roofs  may  require  the  addition  of 
fireproofing, depending on local building/fire codes. 

6. 

In the case that the PV modules are non-integral type, the 
module is to be mounted over a fire resistant roof. 

7. 

Use PV modules with the same cell size within series. 

8. 

Follow all safety precautions of other components that are 
used in the system. 

9. 

In order to avoid a risk of injury or electrical shock, do not 
allow  anyone  to  approach  the  PV  module  if  the  person

 

has little knowledge on PV module or on the measures that 
should be taken when PV modules are damaged. 

10.  Do not shade portions of the PV module surface from the 

sunlight for a long time. The shaded cell may become hot 
(hot  spot  phenomenon)  which  results  in  solder  joints 
peeling  off.

  Shading  causes  drop  in  generated  power 

and/or operation failure of the PV modules. 

11.  Do not clean the glass surface with chemicals. Do not let 

water  collect  on  the  glass  surface  for  a  long  time.  This 
creates a risk of white efflorescence (glass disease) which 
may result in the deterioration of energy generation. 

12.  Do not install the PV module horizontally. It may cause dirt 

or white efflorescence (glass disease) due to water. 

13.  Do not cover the water drain gap of the frame. There is a 

risk  of  frost  damage  when  the  frame  is  filled  with  water 
cumulation. 

14.  If there is a risk of sliding snow, an appropriate measure 

has to be taken so that PV module frames on lower edge 
of PV modules will not be damaged. 

15.  Do  not  expose  PV  module  to  sunlight  concentrated  with 

mirrors, lenses or similar means. 

16.  Turn off inverters and circuit breakers immediately, should 

a problem occur. 

17.  In case the glass surface of a PV module is broken, wear 

goggles and tape the glass to keep the broken  pieces in 
place. 

18.  A  defective  PV  module  may  generate  power  even  if  it  is 

removed from the system. It may be dangerous to handle 
the PV module while exposed to sunlight. Place a defective 
PV module in a carton so PV cells are completely shaded. 

19.  In  case  of  series  connection,  the  maximum  open  circuit 

voltage  must  not  be  greater  than  the  specified  maximum 
system voltage. The voltage is proportional to the number 
of series. In case of parallel connection, please be sure to 
take  proper  measure  (e.g.  fuse  for  protection  of  module 
and  cable  from  over  current,  and/or  blocking  diode  for 
prevention  of  unbalanced  strings  voltage)  to  block  the 

reverse  current  flow.  The  current  may  easily  flow  in  a 
reverse direction

20.  Keep modules away from children. 
 

HANDLING SAFETY  

1. 

Do  not  cause  an  excessive  load  on  the  surface  of  PV 
module  or  twist  the  frame.  The  glass  surface  can  easily 
break. 

2. 

Do not stand or step on the PV module. The surface glass 
of PV module is slippery. 

3. 

Do not hit or put excessive load on the glass or back sheet. 
The PV cell is very thin and can be easily broken. 

4. 

Do not scratch or hit at the back sheet. The back sheet is 
vulnerable. 

5. 

Do not damage the junction box or do not pull the cables. 
The junction box can crack and break. 

6. 

Never touch junction box or the end of output cables with 
bare  hands when the  PV module is irradiated. Cover the 
surface  of  PV  module  with  cloth  or  other  suitable 
sufficiently opaque material to isolate the PV module from 
incident  light  and  wear  rubber  gloves  when  handling  the 
wires to avoid electric shock. 

7. 

Do not scratch the output cable or bend it with force. The 
insulation  of  output  cable  can  break  and  may  result  in 
electricity leakage or shock. 

8. 

Do not pull the output cable excessively. The output cable 
may unplug and cause electricity leakage or shock. 

9. 

Do  not  drill  holes  in  the  frame.  It  may  compromise  the 
frame strength and cause corrosion. 

10.  Do not scratch the insulation coating of the frame (except 

for  grounding  connection).  It  may  cause  corrosion  of  the 
frame or compromise the framework strength. 

11.  Do not touch the PV module with bare hands. The frame of 

PV module has sharp edges and may cause injury. 

12.  Do not drop PV module or allow objects to fall down on the 

PV module. 

13.  Do not concentrate sunlight artificially on the PV module. 
14.  Do  not  hold the PV module  on one side.  The frame may 

bend or twist. Hold the PV module at opposite sides. 

15. 

Do not touch the anti-reflective coated glass since finger 

prints and/or stains can be easily left on the glass surface. 

 

INSTALLATION SAFETY  

1. 

Always  wear  protective  head  gear,  insulating  gloves  and 
safety  shoes  (with  rubber  soles).  Do  not  wear  metallic 
jewellery to prevent electric shock during installation. 

2. 

Keep the PV module packed in the carton until installation. 

3. 

Do  not  touch  the  PV  module  unnecessarily  during 
installation.  The  glass  surface  and  the  frames  get  hot. 
There is a risk of burn, or electric shock. 

4. 

Do not work under rain, snow or windy conditions. 

5. 

Use dry insulated tools. 

6. 

Do not drop tools or hard objects on PV modules 

7. 

When working at heights, wear a safety belt and take care 
not to drop any items (e.g., PV module or tools). 

8. 

Make  sure  flammable  gases  are  not  generated  near  the 
installation site. 

9. 

Completely cover the PV module surface with an opaque 
material during PV module installation and wiring. 

10.  Plug  in  the  connector  tight  and  ensure  the  wiring  work.

 

Make  sure  that  the  connectors  have  been  locked  by  a 
snap-in  latch.  Any  treatments  over  the  connectors  which 
may allow to unlock the snap-in latch shall not be done. 

11.  Due to the risk of electrical shock, do not perform any work 

if the terminals of PV module are wet. 

12.  Do not touch the junction box and the end of output cables, 

the  cable  ends  (connectors)  ,  with  bare  hands  during 
installation or under sunlight, regardless of whether the PV 
module is connected to or disconnected from the system. 

13.  Do  not  unplug  the  connector  if  the  system  circuit  is 

connected to a load. 

14.  Do not stomp on the glass at work. There is a risk of injury 

or electric shock if glass is broken. 

15.  Do  not  work  alone  (always  work  as  a  team  of  2  or  more 

people). 

16.  Do not damage the back sheet of PV modules when setting 

the equipotential bonding by bolts. 

17.  Do not damage the surrounding PV modules or mounting 

structure when replacing a PV module. 

18.  Bind  cables  by  the  insulation  locks.  Drooping  down  of 

cables from the junction box could possibly cause various 

Summary of Contents for NU-AH370

Page 1: ...dically remove any overhanging snow and or ice from the module framework as it may cause deformation of the module frame GENERAL INSTRUCTIONS 1 INTRODUCTION This Installation Manual contains essential information for the electrical and mechanical installation that you must know before installing SHARP PV modules This also contains safety information you need to be familiar with All the information...

Page 2: ...In case of parallel connection please be sure to take proper measure e g fuse for protection of module and cable from over current and or blocking diode for prevention of unbalanced strings voltage to block the reverse current flow The current may easily flow in a reverse direction 20 Keep modules away from children HANDLING SAFETY 1 Do not cause an excessive load on the surface of PV module or tw...

Page 3: ...rame grounding must consider the local requirement and regulation at the installation site When grounding is required please refer to below example connection Figure 3 Please be careful in arranging the system ground so that the removal of one module from the circuit will not interrupt the grounding of any other modules The modules should be grounded to the same electrical point as described below...

Page 4: ...ic modules properly For Information about the proper disposal contact your local recycling site ELECTRICAL OUTPUT AND THERMAL CHARACTERISTICS Rated electrical characteristics of Isc Voc are within 10 percent of the indicated values and 5 0 percent of Pmax power measurement tolerance 3 under STC standard test conditions irradiance of 1000 W m2 AM 1 5 spectrum and a cell temperature of 25 C 77 F Tab...

Reviews: