Installation Manual for PV Modules

C) ELECTRICAL INFORMATION

ELECTRICAL RATINGS

Rated electrical characteristics are within ±10 percent of the indicated values of Isc and Voc and +10/-5 percent of Pmax under Standard Test Conditions 

(irradiance of 100 mW/cm

2

, AM 1.5 spectrum, and a cell temperature of 25˚C (77˚F)). The warranty conditions are specified elsewhere in this manual.

NU-U240F1

NU-U235F1

NU-U235F3

NU-U230F3

Maximum Power (Pmax)

240 W

235 W

235 W

230 W

Open-Circuit Voltage (Voc)

37.4 V

37.0 V

37.0 V

37.0 V

Short-Circuit Current (Isc)

8.65 A

8.60 A

8.50 A

8.40 A

Voltage at maximum power (Vpmax)

30.1 V

30.0 V

30.1 V

30.0 V

Current at maximum power (Ipmax)

7.98 A

7.84 A

7.81 A

7.67 A

Maximum System Voltage

600 V

600 V

600 V

600 V

Minimum Blocking diode

15 A

15 A

15 A

15 A

Series Fuse

15 A

15 A

15 A

15 A

ND-U230C1

ND-U224C1

ND-U216C1

Maximum Power (Pmax)

230 W

224 W

216 W

Open-Circuit Voltage (Voc)

37.0 V

36.9 V

36.7 V

Short-Circuit Current (Isc)

8.24 A

8.07 A

7.85 A

Voltage at maximum power (Vpmax)

30.3 V

30.2 V

30.2 V

Current at maximum power (Ipmax)

7.60 A

7.42 A

7.16 A

Maximum System Voltage

600 V

600 V

600 V

Minimum Blocking diode

15 A

15 A

15 A

Series Fuse

15 A

15 A

15 A

ND-224UC1

ND-220UC1

ND-216UC1

ND-208UC1

ND-200UC1

Maximum Power (Pmax)

224 W

220 W

216 W

208 W

200 W

Open-Circuit Voltage (Voc)

36.6 V

36.5 V

36.5 V

36.3 V

36.01 V

Short-Circuit Current (Isc)

8.33 A

8.24 A

8.10 A

7.99 A

7.90 A

Voltage at maximum power (Vpmax)

29.28 V

29.19 V

28.9 V

28.71 V

28.42 V

Current at maximum power (Ipmax)

7.66 A

7.54 A

7.48 A

7.25 A

7.04 A

Maximum System Voltage

600 V

600 V

600 V

600 V

600 V

Minimum Blocking diode

15 A

15 A

15 A

15 A

15 A

Series Fuse

15 A

15 A

15 A

15 A

15 A

NT-175UC1

NT-170UC1

NE-170UC1

NE-165UC1

Maximum Power (Pmax)

175 W

142 W

170 W

165 W

Open-Circuit Voltage (Voc)

44.4 V

43.2 V

43.2 V

43.1 V

Short-Circuit Current (Isc)

5.40 A

5.47 A

5.47 A

5.31 A

Voltage at maximum power (Vpmax)

35.4 V

34.8 V

34.8 V

34.6 V

Current at maximum power (Ipmax)

4.95 A

4.90 A

4.90 A

4.77 A

Maximum System Voltage

600 V

600 V

600 V

600 V

Minimum Blocking diode

10 A

10 A

10 A

10 A

Series Fuse

10 A

10 A

10 A

10 A

Under normal conditions, a PV module may produce more current and/or voltage than reported at Standard Test Conditions. Accordingly, the values of Isc 

and Voc marked on UL 1703 listed modules should be multiplied by a factor of 1.25 when determining component voltage ratings, conductor ampacities, 

fuse sizes and size of controls connected to the module output. Refer to Sec. 690-8 of the National Electric Code for an additional multiplying factor of 125 

percent (80 percent de-rating) which may be applicable. Where Canadian UL listing applies, installation shall be in accordance with CSA C22.1, Safety 

Standard for Electrical Installations, Canadian Electrical Code, Part 1.

Summary of Contents for NU-U240F1

Page 1: ...cted in parallel current is cumulative PV systems can produce high voltage and current which could present an increased hazard and may cause serious injury or death 5 Do not connect PV modules directly to motor loads Variation in PV module output power as a function of solar irradiance may damage directly connected loads For example 1 In the case of a brushless motor the lock function may become a...

Page 2: ...h the PV module unnecessarily during installation The glass surface and the frame may be hot There is a risk of burns and electric shock 4 Do not work in rain snow or windy conditions 5 Due to the risk of electrical shock do not perform any work if the terminals of the PV module are wet 6 Use insulated tools and do not use wet tools 7 When installing PV modules do not drop any objects e g PV modul...

Page 3: ...ed insulation or insulated with green with yellow stripe s insulation The conductor grounding wire should be 8 12 AWG insulated for 90 C min 4 Fix the ground wire by tightening the screw This will terminate the wire Please contact Ilsco Corporation about item GBL 4DBT 2 Grounding Using Existing Ground Hole Figure 4 The grounding clip Solklip available from Tyco Electronics Corporation part number ...

Page 4: ... is 12 5 N m For your reference please use the washer specified as below for the minimum requirement We recommended parts of the following specifications 1 Spring washer 3 Bolt Material Stainless Steel Material Stainless Steel Diameter M8 5 16 Size M8 5 16 20 mm Thickness 2 mm reference value 2 Washer 4 Nut Material Stainless Steel Material Stainless Steel Diameter M8 5 16 Size M8 5 16 Thickness 1...

Page 5: ... 5 Ver 2 0 _ Mar 15 2010 Installation Manual for PV Modules Figure 9 ND NU series Figure 10 NT NE series Figure 11 ND NU series Figure 12 NT NE series Figure 13 ND NU series Figure 14 NT NE series ...

Page 6: ...W Open Circuit Voltage Voc 36 6 V 36 5 V 36 5 V 36 3 V 36 01 V Short Circuit Current Isc 8 33 A 8 24 A 8 10 A 7 99 A 7 90 A Voltage at maximum power Vpmax 29 28 V 29 19 V 28 9 V 28 71 V 28 42 V Current at maximum power Ipmax 7 66 A 7 54 A 7 48 A 7 25 A 7 04 A Maximum System Voltage 600 V 600 V 600 V 600 V 600 V Minimum Blocking diode 15 A 15 A 15 A 15 A 15 A Series Fuse 15 A 15 A 15 A 15 A 15 A NT...

Page 7: ...warranty period with respect to power output continues for a total of 25 years from date of purchase by the consumer the first 10 years at 90 minimum rated power output and the balance of 15 years at 80 minimum rated power output This warranty is transferable when product remains installed in original location at the time of product warranty registration This warranty does not apply to any alterat...

Page 8: ...umber or serial number of the Product is altered removed or rendered illegible Sharp s aggregate liability in connection with the Product if any shall not exceed the purchase price paid to Sharp for the Product which gave rise to the claim under the Limited Warranty Sharp will not be responsible for any costs associated with labor equipment or materials necessary to remove or re install the Produc...

Reviews: