background image

ENGLISH

Memo

FU-W53J.eng.indd   19

09.10.9   9:19:44 AM

Summary of Contents for Plasmacluster FU-W53J

Page 1: ...ENGLISH R FU W53J AIR PURIFIER OPERATION MANUAL Plasmacluster is a trademark of Sharp Corporation Free standing type ...

Page 2: ...le ments as they repeatedly pass through the filter Some odour ingredients absorbed by the filters may become separated and may be discharged through the air outlet and result in additional odour De pending on the usage environment especially when the product is used in a condition significantly more severe than household use this odour may become strong in a shorter period than expected If the od...

Page 3: ...unique air cleaning technol ogy of the SHARP CORPORATION for breaking down and inactivating such potential allergens as the faecal matter or corpses of aerial mites 1 viruses 2 and mould and bacteria 3 suspended in the air and has been substantiated by third party organisa tions both in Japan and overseas When there is a high density of Plas macluster ions in the air the smell of cigarette smoke t...

Page 4: ...to avoid a hazard Do not operate when using aerosol insecticides or in rooms where there is oily residue incense sparks from lit cigarettes chemical fumes in the air or in very high humidity condition such as a bathroom Be cautious when cleaning the unit Strong corrosive cleansers may damage the exterior Only Sharp Approved Service Centres should service this air purifier Contact your nearest Ap p...

Page 5: ...r wave clocks Avoid a location where the sensor is exposed to direct wind The unit may not operate properly Avoid locations where curtains etc come into contact with the air intake or outlet Curtains etc may become dirty or a unitl malfunction may occur Avoid locations where the unit is exposed to condensation due to drastic temperature changes Use under appropriate conditions between 0 and 35 C i...

Page 6: ...Washable Active Carbon Filter E 4 PART NAMES MAIN UNIT DISPLAY ILLUSTRATIVE DIAGRAM Fan Speed Indicator Lights Filter Reset Indicator Light Plasmacluster ON OFF Indicator Light Plasmacluster Ion ON OFF Button Fan Speed Button ION SHOWER Indicator Light ION SHOWER Mode Button ...

Page 7: ...N with impurities in the air at the time that the air purifier was just introduced to the room environment After a while however the base impurity rate will be adjusted to detect room air condition correctly Green Clean Slightly Impure Very Impure Yellow Red Air Outlet Air Inlet Rating Label Power Cord Plug Handle Dust Sensor Shape of plug depends on country Blue light Plasmacluster ON Light off P...

Page 8: ... filters Remove the Front Panel E 6 Be sure to remove the power plug from the wall outlet FILTER INSTALLATION Remove the Filter Support Pull the Front Panel on the lower sides and lift up 3 2 1 Front Panel 1 Push in the hooks on top then pull the Filter Support Remove the washable Active Carbon Filter Black and HEPA Filter White from the plastic bags Filter Support HEPA Filter Active Carbon Filter...

Page 9: ... between the HEPA Filter and the Filter Support Gently push in the upper tabs left and right to lock in place Fill in the usage start date on the Date Label Use the date as a guide for the Filter Replace ment schedule Replace the Front Panel Bottom tabs HEPA Filter Filter Support Active Carbon Filter Place the Front Panel from the top first then mount the hooks at the bottom Please make sure that ...

Page 10: ...nd HIGH for 20 minutes 10 minutes HIGH fan speed 20 minutes MEDIUM fan speed 20 minutes HIGH fan speed SILENT operation The unit will operate quietly using minimal air intake MEDIUM operation The unit will operate at a fan speed of MEDIUM MAX operation The unit will operate at a fan speed of MAX HIGH fan speed is an inter mediate speed between ME DIUM and MAX ION SHOWER Mode Button When the ION SH...

Page 11: ...on for 3 seconds The Fan Speed Indicator Lights will display the currently set sensor sensitivity level The factory setting is Standard indicated by the MED light 2 3 Press the Fan Speed Button to set the desired sensor sensitivity Refer to the diagram on the right to select the desired sensor sensitivity level Press the Power ON OFF Button Note that if the Power ON OFF Button is not pushed within...

Page 12: ...an the unit including the sen sor and filters periodically When cleaning the unit be sure to unplug the power cord and nev er handle the plug with wet hands Electrical shock and or bodily injury may occur as a result FILTER RESET INDICATOR LIGHT The Filter RESET Indicator Light will illuminate as a reminder to perform mainte nance of the Filters and Sensors The Indicator Light will turn on after a...

Page 13: ...ing or folding the filter when washing 3 Dry filter completely in a well ventilated area If possible dry outdoors Dry filter in a sideways position to avoid warping of the filter The filter takes about 6 hours to dry out 4 Replace the filter in unit See E 6 Dry filter completely before replacing to prevent odours Do not operate unit without all filters properly installed CAUTION CAUTION HEPA Filte...

Page 14: ...ions of airborne particles will cause filters to become clogged in less time Please check filters regularly and replace as needed Up to 5 years after opening Replacement Filters Model HEPA Filter 1 unit FZ W53SFJ Washable Active Carbon Filter 1 unit REPLACING THE FILTERS 1 See page E 6 7 for directions on how to install the filters when replacing 2 Fill in the usage start date of the filters on th...

Page 15: ...eed Indica tor Light blinks Fan motor disconnected or abnormal Operation stops Pressing the POWER ON OFF button will reset the error dis play but if error occurs again contact the shop where you purchased the unit The discharged air has an aroma or odour Check to see if the filters are heavily soiled Replace the filters Plasmacluster Air Purifiers emit small traces of ozone which may produce an od...

Page 16: ...a is appropriate for operating the unit at maximum fan speed Applicable floor surface area indicates the space where a certain amount of dust particles can be removed in 30 minutes JEM1467 Size of a room in which approximately 7000 ions can be measured per cubic centimeter in the center of the room at a height of approximately 1 2 meters from the floor when the product is placed next to a window a...

Page 17: ...ENGLISH Memo ...

Page 18: ...Memo ...

Page 19: ...ENGLISH Memo ...

Page 20: ...China 09K 1 SHARP CORPORATION OF AUSTRALIA PTY LTD A B N 40 003 039 405 1 HUNTINGWOOD DRIVE HUNTINGWOOD N S W 2148 P O BOX 6827 BLACKTOWN N S W 2148 SHARP CORPORATION OF NEW ZEALAND LIMITED 59 HUGO JOHNSTON DRIVE PENROSE AUCKLAND ...

Reviews: