42
E
RS-232C command table
<How to read the command table>
Command:
Command fi eld (See page 35.)
Direction:
W
When the “Parameter” is set in the parameter fi eld (see page 35), the
command functions as described under “Control/Response Contents”.
R
The returned value indicated under “Reply” can be obtained by setting
“????”, “
?” or “???+” (repeater control) in the parameter fi eld (see
page
35).
Parameter:
Parameter fi eld (See page 35.)
Reply: Response
(Returned
value)
* “Yes” indicates commands which can be used in power standby mode.
Power control/Input mode selection
Control item
Command
Direction
Parameter
Reply
Control/Response contents
*
POWER CONTROL
POWR
W
0
Switches to standby mode.
Yes
1
Returns from standby mode.
R
0
Standby mode
1
Normal mode
2
Input signal waiting mode
INPUT MODE SELECTION
INPS
W
0
Toggle change for input mode
Yes
1
PC digital RGB (DVI) (DIGITAL)
2
PC analog RGB (ANALOG)
3
Component (COMPONENT)
4
VIDEO
R
1
PC digital RGB (DVI) (DIGITAL)
2
PC analog RGB (ANALOG)
3
Component (COMPONENT)
4
VIDEO
Controlling the Monitor with a PC