37
E
SETUP menu
Function
Command Direction
Parameter
Reply
Control/Response contents
*
DATE/TIME SETTING
DATE
WR
AABBCCDDEE
AABBCCDDEE
AA: Year, BB: Month, CC: Day, DD: Hour, EE: Minute
○
ID SETTING
ID NO.SETTING
IDST
W
0-25
Sets the monitor’s ID number. (“0” means “no ID number”.)
R
0-25 Returns the monitor’s ID number.
ID NO. SETTING
(ONCE)
IDSL
W
1-25
Sets a monitor ID number.
This ID number is only effective for the command immediately after this
command.
0
Clears the ID number if one has been designated.
ID NO. SETTING
(SUBSEQUENT)
IDLK
W
1-25
Sets a monitor ID number.
This ID number is effective for the next and all subsequent commands after this
command.
0
Clears the ID number if one has been designated.
MULTI
ENLARGE
ENLG
WR
0-1
0-1 0: OFF, 1: ON
ENLARGE MODE
EMHV
WR
11-55
11-55 1 x 1 (OFF) to 5 x 5 (“m x n” is expressed as “mn”, where m and n are the
numbers of monitors specified for the longest direction and the shortest direction
respectively.)
IMAGE POSITION
(M x N)
EPHV
WR
11-55
11-55 Specifies values in the order of IMAGE POSITION IN LONGEST/ SHORTEST
DIRECTION.
BEZEL ADJUST
BZCO
WR
0-1
0-1 0: OFF, 1: ON
ENLARGE/
IMAGE POSITION
SETTING
ESHV
WR
XXYY
XXYY XX: ENLARGE MODE (Same as EMHV), YY: IMAGE POSITION (Same as
EPHV)
THERMAL SENSOR SETTING
STDR
WR
0-1
0-1 0: LANDSCAPE, 1: PORTRAIT
ADJUSTMENT
LOCK
MONITOR
BUTTONS
ALCM
WR
0-1, 3
0-1, 3 0: UNLOCKED, 1: LOCK ALL, 3: LOCK EXCEPT POWER
REMOTE
CONTROL
ALCR
WR
0-3
0-3 0: UNLOCKED, 1: LOCK ALL, 2: LOCK EXCEPT VOLUME,
3: LOCK EXCEPT POWER
Others
Function
Command Direction
Parameter
Reply
Control/Response contents
*
VOLUME
VOLM
WR
0-31
0-31
○
MUTE
MUTE
WR
0-1
0-1 0: OFF, 1: ON
-
INFORMATION
MODEL
INF1
R
Value
○
SERIAL NO
SRNO
R
Value
TEMPERATURE SENSOR
DSTA
R
0 Internal temperature normal
1 Internal temperature abnormal has occurred and the monitor is in standby mode
2 Internal temperature abnormal occurred (To delete the information of temperature
abnormal, turn off the main power.)
3 Internal temperature abnormal has occurred and backlight brightness is dimmed
4 Temperature sensor abnormal
TEMPERATURE ACQUISITION
ERRT
R
Value Returns the temperature at the temperature sensors in the following format.
[Sensor 1]
CAUSE OF LAST STANDBY MODE
STCA
W
0
Initialization
R
0 No detectable error has occurred
1 Standby mode by POWER button
3 Standby mode by RS-232C or LAN
4 Input signal waiting mode by No Signal
6 Standby mode by abnormal temperature
8 Standby mode by SCHEDULE setting
20 Standby mode by OFF IF NO OPERATION setting
LAN SETUP
USERNAME
USER
WR
XXXXXXXX
XXXXXXXX X: Eight characters or less; half-width alphanumeric characters, "-", and "_".
(The field can be left blank, but spaces cannot be entered.)
PASSWORD
PASS
WR
XXXXXXXX
XXXXXXXX X: Eight characters or less; half-width alphanumeric characters, "-", and "_".
(The field can be left blank, but spaces cannot be entered.)
TIPS
• Some menu setting items do not have a command. Set with the remote control during installation.
Controlling the Monitor with a PC (RS-232C)