7
PZ-43HV2, PZ-43HV2E
PZ-43HV2U
Ë
Charged Section
The places where the commercial AC power is used without
passing through the power supply transformer.
If the places are touched, there is a risk of electric shock. In
addition, the measuring equipment can be damaged if it is
connected to the GND of the charged section and the GND of
the non-charged section while connecting the set directly to
the commercial AC power supply. Therefore, be sure to
connect the set via an insulated transformer and supply the
current.
1. AC Power Cord
2. AC Inlet with Filter
3. Power Switch (S1)
4. Fuse (In the SW POWER SUPPLY Module)
5. STB Transformer and Converter Transformer
(In the SW POWER SUPPLY Module)
6. Other primary side of the SW POWER SUPPLY Module
CHARGED SECTION AND HIGH VOLTAGE GENERATING POINT
Ë
High Voltage Generating Point
The places where voltage is 100V or more except for the
charged places described above. If the places are touched,
there is a risk of electric shock.
1. SW POWER SUPPLY Module .............................. (215V)
2. X DRIVE Assy ........................................ (–280V to 215V)
3. Y DRIVE Assy ........................................................ (345V)
4. SCAN (A) Assy ...................................................... (345V)
5. SCAN (B) Assy ...................................................... (345V)
6. X CONNECTOR (A) Assy ..................... (–280V to 215V)
7. X CONNECTOR (B) Assy ..................... (–280V to 215V)
AC Inlet with Filter
Power Cord
Power Switch
(S1)
Fig.1 Charged Section and High Voltage Generating Point (Rear View)
: Part is the High Voltage Generating Points
other than the Charged Section.
: Part is Charged Section.
X DRIVE
Assy
X CONNECTOR (B)
Assy
Y DRIVE
Assy
SCAN (A)
Assy
SCAN (B)
Assy
X CONNECTOR (A)
Assy
SW POWER SUPPLY
Module
Top
Front
∗
Remove the IF Earth Metal
beforehand when inclines the power supply unit
as the right figure.
Summary of Contents for PZ-43HV2
Page 11: ...11 PZ 43HV2 PZ 43HV2E PZ 43HV2U DIMENSIONS Unit mm ...
Page 77: ...81 80 A B C D 5 6 7 5 6 7 8 A B C D 2 3 4 1 2 3 4 PZ 43HV2 PZ 43HV2E PZ 43HV2U Ë SCAN A ASSY ...
Page 78: ...83 82 A B C D 5 6 7 5 6 7 8 A B C D 2 3 4 1 2 3 4 PZ 43HV2 PZ 43HV2E PZ 43HV2U Ë SCAN B ASSY ...
Page 79: ...84 A B C D 2 3 4 1 2 3 4 PZ 43HV2 PZ 43HV2E PZ 43HV2U Ë X CONNECTOR A and B ASSYS ...
Page 80: ...85 A B C D 1 2 3 1 2 3 4 PZ 43HV2 PZ 43HV2E PZ 43HV2U Ë BRIDGE A D ASSYS ...
Page 81: ...86 A B C D 2 3 4 1 2 3 4 PZ 43HV2 PZ 43HV2E PZ 43HV2U Ë CLAMP A and B ASSYS ...
Page 82: ...87 PZ 43HV2 PZ 43HV2E PZ 43HV2U ...
Page 118: ...158 A B C D 2 3 4 1 2 3 4 PZ 43HV2 PZ 43HV2E PZ 43HV2U Ë SP TERMINAL ASSY ...
Page 119: ...159 PZ 43HV2 PZ 43HV2E PZ 43HV2U ...
Page 122: ...164 A B C D 2 3 4 1 2 3 4 PZ 43HV2 PZ 43HV2E PZ 43HV2U Ë SW POWER SUPPLY MODULE 3 3 ...
Page 138: ...185 A B C D 1 2 3 1 2 3 4 PZ 43HV2 PZ 43HV2E PZ 43HV2U MR INTERFACE ASSY ANP1997 B SIDE B ...