R - 2 2 A T
R-23AM
R - 2 4 A T
REMEMBER TO CHECK 3D
1) Disconnect the supply.
2) Door opened, and wedged open.
3) Discharge high two voltage capacitors.
WARNING: AGAINST THE CHARGE OF THE TWO
HIGH-VOLTAGE CAPACITORS.
The two high-voltage capacitors remain charged
about 60 seconds after the oven has been switched
off. Wait for 60 seconds and then short-circuit the
connection of the two high-voltage capacitors (that
is, of the connecting lead of the high-voltage recti-
fier) against the chassis with use of an insulated
screwdriver.
Sharp recommend that wherever possible fault-finding
is carried out with the supply disconnected. It may, in
some cases, be necessary to connect the supply after
the outer case has been removed, in this event carry out
3D checks and then disconnect the leads to the primary
of the power transformer. Ensure that these leads re-
main isolated from other components and the oven
chassis. (Use insulation tape if necessary.) When the
testing is completed carry out 3D checks and reconnect
the leads to the primary of the power transformer.
SERVICING
WARNING TO SERVICE PERSONNEL
Microwave ovens contain circuitry capable of producing very high voltage and current. Contact with following parts
will result in electrocution.
High voltage capacitors, High voltage transformers, Magnetrons, High voltage rectifier assembly, High voltage
fuses, High voltage harness.
REMEMBER TO CHECK 4R
1) Reconnect all leads removed from components dur-
ing testing.
2) Replace the outer case (cabinet).
3) Reconnect the supply.
4) Run the oven. Check all functions.
Microwave ovens should not be run empty. To test for
the presence of microwave energy within a cavity, place
a cup of cold water on the oven turntable, close the door
and set the microwave timer for one (1) minut. When the
one minute has elapsed (timer at zero) carefully check
that the water is now hot. If the water remains cold carry
out 3D checks and re-examine the connections to the
component being tested.
When all service work is completed and the oven is fully
assembled, the microwave power output should be
checked and microwave leakage test should be carried
out.
1800W/R-23AM
START
HIGH
MEDIUM
MED LOW
DEFROST
TIME
CONTROL
R-23AM