5
Perform Simulation 48-01 =
↵
.
C
→
=
↵
→
0/
◊
→
=
↵
→
4
→
8
→
PSW
→
1
→
PSW causes a preset value of longitudinal magnifica-
tion to be indicated.
6
Determine a preset value of longitudinal magnification according
to the following expression:
Preset value of longitudinal magnification = previous preset
value(indicated at step
5
) + [correction factor for longitudinal
magnification x 10]
Eg.: Preset value = 25 + [1 x 10] = 35
7
Type the preset value of longitudinal magnification:
→
→
PSW
Changing the preset by "1" provides the magnification change of
0.1 %.
8
Take a full-size copy of the scale and compare the image length
with the scale length.
9
The image length must be the same as the scale length. Other-
wise, repeat the above steps
1
to
8
until this requirement is
met.
F
Press the clear all key to clear Simulation 48.
(4) Adjusting the Resolution
1
Perform Simulation 48-01 to check that a preset value cor-
responds to a focal length of lens used:
C
→
0/
◊
→
0/
↵
→
=
↵
→
4
→
8
→
PSW
→
1
→
PSW .
When the ready lamp is lit, a preset value is indicated.
2
If no preset value exists, set a reference value according to
(2)"Adjusting the reference position of 4. and 5. mirror". Then
take a copy of "UKOG-0089CSZZ" and check the resolution.
3
When changing a preset value:
→
→
PSW .
Checking Procedure
After adjusting the reference position of 4. and 5. mirror, check as
follows:
1
Set the test chart UKOG-0089CSZZ or a resolution test chart on
the original table.
2
Take a full-size copy.
3
Check if the center and corners of the copy paper is in focus.
4
The resolution must be at least 5.0 lines/mm in the center and
4.5 lines/mm in the corners. Otherwise, repeat the steps
2
to
4
of (2) while changing the preset value by 1 at a time, until this
requirement is met.
Applied Material: UKOG-0089CSZZ (Test chart)
10
20
90
100
110
1mm
10
20
90
100
110
100 mm-scale (original)
Image, of which length
is shorter than the
original by 1 mm(1%).
Check if the center and
corners is in focus
Copy paper
(A3 or 11" x 17")
SIMULATION NO.48-
*
1. FRONT/REAR MAGNIFICATION RATIO ADJUSTMENT
2. PAPER TRANSPORT DIRECTION MAGNIFICATION RATIO ADJUSTMENT
FRONT/REAR MAGNIFICATION RATIO ADJUSTMENT
45MB:
LENS:
7 – 9
Summary of Contents for SF-2040
Page 27: ...9 Desk unit SF D23 11 12 16 17 13 18 10 9 8 7 6 2 5 4 3 1 23 21 22 19 20 14 15 4 10 ...
Page 63: ...5 5 C F 10 D 7 6 11 G E 8 9 H 12 6 2 ...
Page 65: ...3 B 3 E 13 C 4 5 6 7 8 F 14 D 10 11 9 6 4 ...
Page 67: ...2 1 3 A D 9 8 11 10 B 4 5 E 12 13 14 C 7 6 6 6 ...
Page 69: ...A a 1 1 D 4 4 B 1 b 1 1 E 5 5 7 6 8 9 8 5 C 2 3 3 F 5 11 12 6 8 ...
Page 71: ...1 2 3 3 4 5 A D 13 11 10 7 6 6 7 B E 14 8 12 9 C F 15 G 16 16 6 10 ...
Page 73: ...A a 1 D 11 10 10 9 8 B 4 2 3 E 13 12 12 C 5 7 6 7 6 12 ...
Page 75: ...C 4 F 9 9 9 10 9 5 6 D G 11 E 8 7 6 14 ...
Page 78: ...Volume PWB 8 9 10 10 6 17 ...
Page 80: ...C 5 F 11 P D F R 7 6 6 12 13 G 12 13 E 8 9 a 8 H 14 6 19 ...