25
STATUS INDICATORS
2
Turn the roller rotating knob in the direction of the arrow
and remove the paper from the fusing unit area.
CAUTION
The fusing unit is hot! Use care in removing paper.
3
If the misfed paper is in the exit area, open the exit area
cover carefully.
●
Open the cover by pulling the lever up. Support it until fully open.
●
If an optional sorter is installed, slide it away from the copier and
then open the cover.
4
Turn the roller rotating knob in the direction of the arrow
and remove the paper.
●
If the misfed paper is deep in the fusing unit, lift the fusing unit
tab and remove any misfed paper.
CAUTION
The fusing unit is hot! Be sure to touch only the green tab or the
green roller rotating knob.
5
Close the exit area cover.
6
Close the front cover.
●
Confirm that the
indicator has gone out.