SJGF60XT
25
PLASMACLUSTER OK/NG JUDGMENT
5.
Judgment procedure
1)
Disconnect the power supply, and keep the refrigerator compartment door opened for 5 minutes or longer to raise
1.
the temperature in the refrigerator compartment.
After closing the refrigerator compartment door, connect the power supply, and turn ON the plasmacluster.
2.
(When the plasmacluster is turned ON, the blue LED in the compartment and plasmacluster [
クリーン
] of control
panel on the door are ON.)
Check the ion at the PCI discharge port with the ion measuring instrument.
3.
Refrigerator compartment: Measure PCI while pressing the door switch.
If at least either ion quantity (+ or -) is indicated, the judgment result is acceptable.
4.
This procedure is intended for simplified check of fan motor and plasmacluster operations. Even if the ion
•
quantity specified in the catalog cannot be confirmed, it is no problem. *
* Reason why the ion quantity speci
fi
ed in the catalog cannot be con
fi
rmed:
Because the ion quantity specified in the catalog has been measured in stable operating conditions with the
•
refrigerator compartment door closed.
If the ion measuring instrument is inserted/removed when the compartment is cooled, condensation occurs with
•
the measuring instrument, which disables reliable ion quantity check due to a measuring error.
Measuring position
2)
During PCI operation
PCI measuring position
Refrigerator
compartment
Ice
compartment
Freezer
compartment
(Upper)
Freezer
compartment
(Lower)
Vegetable
compartment