THE MICROWAVE MUST BE LEVEL
Use a level to make sure the cabinet bottom is level. If the cabinets
have a front overhang only, with no back or side frame, the top
line of Rear Wall Template must align with below cabinet bottom,
the same distance as the front overhang depth. This will keep the
microwave level.
1.
Measure the inside depth of the front overhang.
2.
Draw a horizontal line on the back wall, an equal distance below
the cabinet bottom as the inside depth of the front overhang.
3.
For this type of installation with front overhang only, align top
line of Rear Wall Template with this horizontal line, not touching
the cabinet bottom as described in step D.
Note:
Your cabinets may have decorative trim that interferes with
the microwave installation. Remove the decorative trim to install
the microwave properly and to make it level.
D. ALIGN TOP LINE OF REAR WALL TEMPLATE
Area E
Center line
CAUTION
Wear gloves to avoid cutting fingers on sharp edges.
1.
Using tape measure, draw a vertical line on the wall at the center
of the 24" (61 cm) wide space.
2.
Tape the Rear Wall Template on the cabinet wall, align the center
markers on the Rear Wall Template to the center line on wall,
making sure it is level and that the top line of the Rear Wall
Template is butted up against the bottom edge of the upper cabinet.
3.
While taping the Rear Wall Template on the wall, draw circles
on the wall at hole A, B, C (see illustration above/actual plate
marked with arrows). THREE HOLES MUST BE USED FOR
MOUNTING. (If there are 2 wall studs in right and left side based
on center line, four holes must be used for mounting.)
4.
Remove the Rear Wall Template and check the marking based on
the actual mounting plate (center line, holes A, B, C).
5.
Drill holes on the circle marks (A, B, C). Drill a
3
/
16
" (4.7 mm)
hole at C for lag screw and two
5
/
8
" (15.88 mm) holes at A and
B for toggle bolts.
Note:
DO NOT MOUNT THE PLATE AT THIS TIME.
6.
If the Rear Wall Template is damaged or unusable, measure and
mark the wall with the dimensions described in step E.
E. MARK REAR WALL OF THE CABINET WITHOUT REAR
WALL TEMPLATE
1.
The Bottom edge line of Mounting Plate must be 17
1
/
8
" (435 mm)
from the bottom edge line of upper cabinet and must be level.
STEP-BY-STEP INSTALLATION GUIDE
2.
Mounting plate end holes must be 16
11
/
16
" (423.8 mm) from the
bottom edge line of upper cabinet and must be on a equal line
with each other. They must each be 9
3
/
8
" (237.8 mm) from the
center line.
Bottom edge line of upper cabinet
Mounting plate end hole
(right/left)
16
11
/
16
"
(423.8 mm)
17
1
/
8
"
(435 mm)
Bottom edge line of
mounting plate
9
3
/
8
"
(237.8 mm)
9
3
/
8
"
(237.8 mm)
INSTALLATION TYPES
(CHOOSE A, B OR C)
This microwave oven is designed for adaptation to the following
three types of ventilation:
A. OUTSIDE TOP EXHAUST (VERTICAL DUCT)
See page 11.
Adapter in place
for outside top exhaust
B. OUTSIDE REAR EXHAUST (HORIZONTAL DUCT)
See page 13.