5
SX51LF7
SX51LF8
5-1
5-2
USER DA
T
A
CONTRAST
MAX (64/64)
COLOUR
CENT (32/64)
BRIGHTNESS
CENT (32/64)
TINT
CENT (32/64)
SHARPNESS
CENT (32/64)
WHITE TEMP
CENT (32/64)
TREBLE
CENT (32/64)
BASS
CENT (32/64)
SURROUND
OFF
BALANCE
CENT (32/64)
S-VOLUME
MIN (1/64)
BLUE BACK
OFF
C SYSTEM
AUT
O
S SYSTEM
*1
USER DA
T
A
IN SER
VICE MODE
* While SER
VICE mode ON, EEPROM DA
T
A
will switch to the service data.
Also, once SER
VICE mode OFF
, EEPROM will switch back to previous USER DA
T
A
.
* In the service mode, the user data establish as below
,
*1: For each CH, data is
same as before switch
to service Mode.
* Direct Key-in
MODE
KEY
-IN KEY
AGC
FUNCTION
SUB-BRI
BRIGHTNESS UP
DRI-GS
TEXT
DRI-BS
PICTURE
CUT
-R
SKIP
CUT
-G
F2
V
-LIN
CONTRAST DOWN
V
-CENT
BRIGHTNESS DOWN
V
-AMP
COLOUR DOWN
H-CENT
TINT DOWN
H-SIZE
BALANCE RIGHT
P
ARA
TREBLE UP
TRAPE
BASS UP
EW//
SHARPNESS DOWN
SUB-COL
COLOUR UP
SUB-TINT
TINT UP
EEPROM ITEMS
OSD
DA
T
A
LENGTH
INITIAL
DA
TA
FIX/ADJ
REMARK
AGC
T
ake Over Point
AGC
0 ~ 63
14 (20)
ADJ
V
ertical Slope
V
-LIN
0 ~ 63
32
ADJ
V
ertical
Amplitude
V
-AMP
0 ~ 63
32
ADJ
V
ertical Shift
V
-CENT
0 ~ 63
32 (15)
ADJ
Horizontal shift
H-CENT
0 ~ 63
32
ADJ
East-W
est width
H-SIZE
0 ~ 63
32
FIX
Horizontal Parallelogram
EW / /
0
~ 63
32
FIX
East-west Parabola/Width
P
ARA
0 ~ 63
32
FIX
East-west Upper Corner Parabola
COR (U)
0 ~ 63
32
FIX
East-west Lower Corner Parabola
COR (L)
0 ~ 63
32
FIX
East-west
T
rapezium
TRAPE
0 ~ 63
32
FIX
Horizontal Bow
HB
0 ~ 63
32
FIX
S-Correction
S-COR
0 ~ 63
0 (24)
FIX
White point Red Standard white temp.
DRI-RS
0 ~ 63
32
FIX
White point Green Standard white temp.
DRI-GS
0 ~ 63
32
ADJ
White point Blue Standard white temp
DRI-BS
0 ~ 63
32
ADJ
White point Red Cold white temp.
DRI-RC
0 ~ 63
25
FIX
White point Green Cold white temp.
DRI-GC
0 ~ 63
32
FIX
(DRI-GS)-7 DA
T
A
White point Blue Cold white temp.
DRI-BC
0 ~ 63
32
FIX
(DRI-BS) DA
T
A
White point Red W
arm white temp.
DRI-R
W
0
~ 63
32
FIX
White point Green W
arm white temp.
DRI-GW
0 ~ 63
32
FIX
(DRI-GS)-7 DA
T
A
White point Blue W
arm white temp.
DRI-BW
0 ~ 63
32
FIX
(DRI-BS)-7 DA
T
A
Max V
olume
SUB-VOL
0 ~ 60
60
FIX
Sub Contrast
SUB-CON
0 ~ 63
63
FIX
Sub Colour
SUB-COL
0 ~ 63
32 (20)
ADJ
Sub Brightness
SUB-BRI
0 ~ 63
32 (20)
ADJ
Sub
T
int
SUB-TINT
0 ~ 63
32 (30)
ADJ
Sub Sharpness
SUB-SHP
0 ~ 63
32
FIX
Max Hotel V
olume
HTL-VOL
0 ~ 60
30
FIX
Hotel Program number
HTL-PRG
0 ~ 99 OR >99 FOR NONE
255
FIX
Blue Back Contorast
BB-CON
0 ~ 15
10
FIX
OSD RGB Reference
RGB
0 ~ 15
15 (8)
FIX
Black Level of
f-set R
CUT
-R
0 ~ 63
32
ADJ
Black Level of
f-set G
CUT
-G
0 ~ 63
32
ADJ
Cathode Drive Level
CDL
0 ~ 15
0 (9)
FIX
Y
-Delay time for P
A
L
(TV)
DL-PT
0 ~ 15
12
FIX
Y
-Delay time for SECAM (TV)
DL-ST
0 ~ 15
15
FIX
Y
-Delay time for N358 (TV)
DL-3T
0 ~ 15
12(5)
FIX
Y
-Delay time for N443 (TV)
DL-4T
0 ~ 15
12(5)
FIX
Y
-Delay time for B/W (TV)
DL-TV
0 ~ 15
12
FIX
Y
-Delay time for P
A
L
(A
V)
DL-P
A
0 ~ 15
12
FIX
Y
-Delay time for SECAM (A
V)
DL-SA
0 ~ 15
15
FIX
Y
-Delay time for N358 (A
V)
DL-3A
0 ~ 15
12(5)
FIX
Y
-Delay time for N443 (A
V)
DL-4A
0 ~ 15
12(5)
FIX
Y
-Delay time for B/W (A
V)
DL-A
V
0 ~ 15
12
FIX
After short
TP1001 &
TP1002, and turn on the MAIN POWER switch, read data from EEPROM address
00H ~ 03H, and compare to the list below
, if dif
ferent, initialize the EEPROM.
Address
:
Data
Address
:
Data
00H
:
55H
02H
:
53H
01H
:
41H
03H
:
36H