SW-G3 No. 3, No. 4 Section time of quiet detection
The switch which sets the time from the start of detection function to the
end of the function.
SW-G3 No. 5 ~ No. 8 Reserved
Set to "0"
SW-G4 No. 1 ~ No. 6 Quiet detect level setting
(0~-44dBm setting by 1dBm step)
This is used to change the quiet detect level setting.
If quiet detection is difficult due to noise, reduce this setting level.
(Example)
Factory setting : 1 0 1 1 0 0 (- 44dBm)
↓
1 0 1 0 0 0 (- 40dBm)
SW-G4 No. 7 Fax switching when A.M. full
If the answering machine’s memory (tape) is full and there is no response,
the machine automatically switches to Fax reception.
SW-G4 No. 8 Reserved
Set to "0".
SW-H1 No. 1 Busy tone continuous sound detect time
Set detecting time busy tone continuous sound for 5 seconds or 10 sec-
onds.
SW-H1 No. 2 Reserved
Set to "0".
SW-H1 No. 3 Busy tone detect continuation sound detect
Used to select detection of the continuous sound of certain frequency.
SW-H1 No. 4 Reserved
Set to "0".
SW-H1 No. 5 Busy tone detect intermittent sound detect
Used to select detection of the intermittent sound of certain frequency.
SW-H1 No. 6, No. 7 Busy tone detection pulse number
Used to set detection of Busy tone intermittent sounds.
SW-H1 No. 8 Reserved
Set to "0".
SW-H2 No. 1, No. 2 Busy tone detection ON/OFF time(Lower limit)
The initial value of detection is set according to electric condition.
The set value is changed according to the local switch board. (Errone-
ous detection of sound is reduced.)
If erroneous detection is caused by sound, etc., adjust the detection
range.
The lower limit can be set in the range of 150msec to 350msec.
SW-H2 No. 3, No. 4 Busy tone detection ON/OFF time (Upper limit)
Similarly to SW-H2 No. 1, No. 2, the set value can be varied.
The upper limit can be set in the range of 650msec to 2700msec.
SW-H2 No. 5 ~ No. 8 Reserved
Set to "0".
SW-I1 No. 1 ~ No. 7 Reserved
Set to "0".
SW-I1 No. 8 CPC signal detection
Used to turn ON/OFF the CPC (Calling Party Control) signal detection.
SW-I2 No. 1 ~ No. 5 Reserved
Set to "0".
SW-I2 No. 6 ~ No. 8 CPC detection time
Used to set the CPC (Calling Party Control) signal detect time.
SW-I3 No. 1 ~ No. 8 Reserved
Set to "0".
SW-I4 No. 1 ~ No. 8 Reserved
Set to "0".
SW-I5 No. 1 ~ No. 8 Reserved
Set to "0".
SW-I6 No. 1 ~ No. 8 Reserved
Set to "0".
SW-I7 No. 1 ~ No. 8 Reserved
Set to "0".
SW-I8 No. 1 ~ No. 8 Reserved
Set to "0".
SW-J1 No. 1 Sender's phone number setting
Used to make a choice of whether the registered sender's phone number
can be changed or not. If the switch is set to "1", new registration of the
sender's phone number is disabled to prevent accidental wrong input.
SW-J1 No. 2 Summer time setting
Used to set YES/NO of automatic clock adjustment for Summer time.
SW-J1 No. 3, No. 4 Ringer Volume
Used to adjust ringing volume.
SW-J1 No. 5, No. 6 Speaker Volume
Used to adjust sound volume from a speaker.
SW-J1 No. 7 Polling key
If this switch is set to 1, the last of Rapid key works as polling key.
SW-J1 No. 8 Reserved
Set to "0".
SW-J2 No. 1 ~ No. 6 Reserved
Set to "0".
SW-J2 No. 7 Saving energy start timing
Used to set the time between the machine’s stand-by state (clock indi-
cation) after operation and saving energy mode.
It is possible to set the time to either 5 sec or 180 sec (default).
SW-J2 No. 8 Saving energy mode
Used to select whether to make the saving energy mode valid or not.
SW-J3 No. 1 ~ No. 3 Communication results printout
(Transaction report)
It is possible to obtain transaction results after each communication.
Normally,the switch is set (No. 1 : 0, No. 2 : 0, No. 3 : 0) so that the
transaction report is produced only when a communication error is en-
countered.
If No.1 was set to 0 and No. 2 to 1 and No. 3 to 0, the transaction report
will be produced every time a communicaion is done, even if the
communicaion was successful.
Setting No. 1 to 0 and No. 2 to 1 and No. 3 to 1 will disable this function.
No transaction report printed.
SW-J3 No. 4 Time format
When set to "0", 24hour time format is used.
When set to "1", 12hour time format is used.
SW-J3 No. 5 Date format
When set to "0", Day-Month-Year format is used.
When set to "1", Month-Day-Year format is used.
SW-J3 No. 6 ~ No. 8 Reserved
Set to "0".
SW-K1 No. 1 Entering diag mode by pressing SPEED key
A bit which is used in the production process only. When the SPEED key
is pressed, the switch is changed from the stand-by state to the diag
mode.
SW-K1 No. 2 ~ No. 8 Reserved
Set to "0".
Summary of Contents for UX-40
Page 12: ...1 10 UX 40H UX 60H M E M O ...
Page 45: ...UX 40H UX 60H 3 14 M E M O ...
Page 67: ...UX 40H UX 60H Control PWB parts layout Top side 6 7 ...
Page 68: ...UX 40H UX 60H Control PWB parts layout Bottom side 6 8 ...
Page 71: ...UX 40H UX 60H TEL LIU PWB parts layout Top side 6 11 ...
Page 72: ...UX 40H UX 60H 6 12 TEL LIU PWB parts layout Bottom side ...