31
Function parameters for
%
,
&
and
-
*: Item:
Selection:
Entry:
A
+/- sign
+ (premium) sign
0
- (discount) sign*
1
B
Item % / Item
_
Allow*
0
Disallow
1
C
Subtotal % / Subtotal
_
Allow*
0
Disallow
1
D
Entry digit limit for discount key
0-8 (default:8)
When programming for percent keys, always enter 0 for D.
+/- sign
• Programming of the +/- sign assigns the premium or discount function for each key.
Item % / Item
_
_
• Percent/discount calculation for the individual department and PLU
Subtotal % / Subtotal
_
_
• Percent/discount calculation for the subtotals
Entry digit limit (For discount key only)
• The entry digit limit is in effect for the REG-mode operations but can be overridden in the MGR mode. The
entry digit limit is represented by the number of allowable digit for the maximum entry amount for discount
key. When “0” is set, open price entry is prohibited.
Function parameters for
V
*: Item:
Selection:
Entry:
A
Open rate entry
Allow*
0
Disallow
1
B
Preset rate entry
Allow*
0
Disallow
1
C
Position of decimal point (from right) (tab)
0-3 (default:2)
From left, ABC
102
@
V A
Key operation example
*ABC
A
To program “0” for all items
@
V
From left, BCD
Sign(A)
1006
@
- A
Key operation example
*ABCD
or
%
@
-
A
&
To program for another key
To program “0” for all items
A201_3 FOR THE MANAGER 01.11.11 10:22 AM Page 31