2. Simulation list
Main code
Sub code
Content
1
1
Mirror base operation check, optical system sensor status display
1
2
Optical system sensor status display
1
3
Lens, No. 4/5 mirror operation check
1
4
Lens, No. 4/5 mirror aging
5
1
Operation panel display check
5
2
Heater lamp check
5
3
Copy lamp check
5
4
Discharge lamp check
5
5
Blank lamp check
7
1
JAM aging
7
6
Intermittent aging
8
1
Developing bias check
8
2
Main charger/transfer charger output check (Manual copy mode)
8
3
Main charger/transfer charger output check (Photo copy mode)
8
4
Main charger/transfer charger output check (Toner save mode)
10
—
Toner motor operation check
14
—
Cancel of trouble other than U2 trouble
16
—
Cancel of U2 trouble
22
5
Total counter display
22
12
Drum counter display
24
7
Drum counter clear
25
1
Main motor operation check
26
1
Manual mode (single/multi) setting
26
6
Destination setting
26
7
Machine conditions setting
26
11
Exposure adjustment value setting for OPC drum membrane decrease correction
26
20
Rear edge void setting
30
1
Paper sensor status display
43
1
Fusing temperature setting
43
4
Fusing temperature in multi copy
46
1
Exposure level adjustment
(Note 1)
47
—
AE sensor characteristics measurement
48
1
Vertical/horizontal copy magnification ratio adjustment and zooming exposure correction setting (Note 1)
50
1
Lead edge image position adjustment and void adjustment (lead edge/rear edge)
(Note 1)
51
2
Resist amount adjustment
(Note 1)
*
In the simulation mode (except for the aging mode):
While pressing % key, press the 1-digit up key, and the key will be the 1-digit down key.
While pressing % key, press the 10-digit up key, and the key will be the 10-digit up key.
(Note 1) When the simulation mode is canceled by pressing the clear key while copying, be sure to check that the lens is stationary (Ready lamp
ON) before pressing the clear key.
(Reason) If the clear key is pressed during the lens is moving (normal
→
zooming, zooming
→
normal, zooming
→
zooming), the
magnification ratio displayed on the operation panel does not correspond to the lens stop position, resulting in copying of a
different magnification ratio than that displayed on the operation panel.
If the clear key is erroneously pressed during the lens is moving, turn OFF/ON the power to initialize the lens.
10 – 2
www.freeservicemanuals.info
1/11/16
Published in Heiloo, Holland.