Main code
Sub code
Content
8
3
Main charger, transfer charger voltage check (Phot copy mode)
(Operation/procedure)
The main charger and the transfer charger are turned on for 30 sec in the photo copy mode.
Check that the output is –400
±
10V. If not, adjust.
4
Main charger, transfer charger voltage check (Toner save mode)
(Operation/procedure)
The main charger and the transfer charger are turned on for 30 sec in the toner save copy mode.
Check that the output is –500
±
8V. If not, adjust.
10
Toner motor and the control circuit operation check
(Operation/procedure)
The toner motor is turned on for 30 sec.
14
Cancel of trouble other than U2
(Operation/procedure)
After canceling the trouble, the simulation is automatically canceled.
16
Cancel of U2 trouble
(Operation/procedure)
After canceling the trouble, the simulation is automatically canceled.
22
5
Total count value check
(Operation/procedure)
The total count value is displayed in 2 digits
×
3 times on the COPY QUANTITY display repeatedly. There is a blank
between displays. The display after the longest blank shows the top digits.
(Example)
00
→
31
→
46
In the above case, the value is 3,146.
12
Drum (CRU) counter value check
(Operation/procedure)
The CRU drum counter value installed is checked.
(Example)
00
→
31
→
46
In the above case, the value is 3,146.
24
7
Drum counter clear
When this simulation is executed, the drum counter will be "0."
25
1
Main motor and the control circuit operation check
(Operation/procedure)
The main motor is operated and the developing bias is turned on for 30 sec.
26
1
Manual paper feed section setting
(Operation/procedure)
When this simulation is executed, the currently set bypass code number is displayed. Enter the code number
corresponding to the bypass and press the COPY key to set the bypass.
Code No.
Bypass
0
Single bypass
1
Multi bypass
6
Destination setting
(Operation/procedure)
When this simulation is executed, the currently set destination code number is displayed.
Enter the code number corresponding to the destination and press the COPY key to set the destination.
Code No.
Destination
0
Inch series
1
AB series
10 – 4
www.freeservicemanuals.info
1/11/16
Published in Heiloo, Holland.