background image

GROUNDING INSTRUCTIONS

This appliance must be properly grounded. If it should mal-
function or break down, grounding provides a path of least
resistance for electric current to reduce the risk of electric
shock. This appliance is equipped with a cord having an equip-
ment-grounding conductor and grounding plug. The plug
must be inserted into an appropriate outlet that is properly
installed and grounded in accordance with all local codes and
ordinances.

WARNING: Improper connection of the equipment-ground-
ing conductor can result in a risk of electric shock. Check with
a qualified electrician or service person if you are in doubt as
to whether the outlet is properly grounded. Do not modify the
plug provided with this appliance. If the plug will not fit the
outlet, have a proper outlet installed by a qualified electrician.

This appliance is for use in a nominal 120-volt circuit, and has
a grounded plug that looks like the plug illustrated in sketch A.
A temporary adapter that looks like the adapter illustrated in
sketches B and C may be used to connect this plug to a 2-pole
receptacle as shown in sketch B if a properly grounded outlet is
not available. The temporary adapter should be used only until
a properly grounded outlet (sketch A) can be installed by a
qualified electrician. The rigid lug (usually green) extending
from the adapter must be connected to a permanent ground,
such as a properly grounded outlet box cover. Whenever the
adapter is used, it must be held in place by a metal screw.

Grounding Pin

Grounded Outlet

A

B

C

Metal Screw

Lug for Grounding Screw

Summary of Contents for Steam Wizard SM420

Page 1: ...S St te ea am m W Wi iz za ar rd d S SM M4 42 20 0 I IN NS ST TR RU UC CT TI IO ON NS S INCLUDES IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE SAVE THESE INSTRUCTIONS ...

Page 2: ...power cord must only be replaced by qualified service personnel There are no user serviceable parts inside the unit Any attempt to open the unit will void the warranty and could lead to serious damage to the unit and or personal injury to the operator Turn off all controls before unplugging unit from outlet Do not unplug by pulling the cord Grasp the plug itself when unplugging from an outlet not ...

Page 3: ...modify the plug provided with this appliance If the plug will not fit the outlet have a proper outlet installed by a qualified electrician This appliance is for use in a nominal 120 volt circuit and has a grounded plug that looks like the plug illustrated in sketch A A temporary adapter that looks like the adapter illustrated in sketches B and C may be used to connect this plug to a 2 pole recepta...

Page 4: ...SQUEEGEE Attach by inserting into the nozzle to clean floors and other hard surfaces BRUSH Attach by inserting into the nozzle to clean upholstery and other fabric WITHOUT WATER Used to pick up wet or dry spills and messes STEAM ONLY Used to pick up stains before they have a chance to set STEAM SPRAY Used to pick up stubborn stains and old stains that have dried Can damage items if too much water ...

Page 5: ...unterclockwise Slowly pour unheated cool water into the opening Leave at least 1 2 inch of air space in the water tank Replace the water tank cap by twisting clockwise until it resists further tightening about 1 4 turn Do not over tighten The cap will lock into place as indicated on the opening of the tank Maximum water level NOTE If the cap is difficult to remove loosen by running under warm wate...

Page 6: ...ntrol to VACUUM Glide the nozzle over the debris or spill until it has been vacuumed into the collection chamber Do not allow the collection chamber to become too full When cleaning carpet use the unit without any of the attachments in place When cleaning hard surfaces use with the rubber squeegee attachment inserted into the nozzle of the Steam Wizard TURBO STEAM OFF ON SPRAY STEAM OFF VACUUM ...

Page 7: ...M SPRAY position can be used to dilute the stain with hot water Do not over saturate the area with water Glide the nozzle over the stained area until the stain is lifted Once the stain is removed excess water can be removed by switching to VACUUM Do not allow the collection chamber to become too full When steam cleaning carpet use the unit without any of the attachments in place Use the brush atta...

Page 8: ...ssemble the unit to continue using the Steam Wizard Once cleaning is complete the chamber and attachments should be washed in warm soapy water before final reassembly and storage To empty the water tank unplug the unit from the wall and hold it over a drain or sink Remove the water tank cap and turn the nozzle up to drain the excess water from the tank DO NOT over tighten the water tank cap when r...

Page 9: ... be able to eliminate the spill with the lowest possible risk for permanent damage Boost your cleaning power by using a spray bottle to mist over the soiled area with a cleaning agent Let the mist settle on the stain for a minute and then clean with the Steam Wizard Use cleaning agents only as a last resort Type of stain Tough Stains and Suggested Agents for Cleaning Best reaction Optional agent F...

Page 10: ...he event repair is not possible The Sharper Image will either replace this product with one of similar features and price or refund the full purchase price of the product whichever you prefer How to Obtain Service Return the product and receipt along with a brief explanation of the problem to T S I Returns Department 2901 A West 60th Street Little Rock AR 72209 If you have questions please feel fr...

Reviews: