2013GK8005
-6-
2. In order to reach the wind load and snow load, our suggestion is to dig 1.5m deep hole
for the anchors. There are 3 Anchors (No. Q) for each hole (2 anchors for front and back
panel).
B--FRAME INSTALLATION
1. As “Main Arch Sketch” shows, connect Rafter (No.B1 to B6) to Upright (No.A1 to A6)
by Bolt M16 (No.K, the high strength bolt for steel structure) to be an arch. There are
6pcs of bolts for every two parts and 6 arches for 15m long tent
.
Main Arch Sketch