background image

- 2 - 

Unit (mm) 

 

Power supply input

 

 

The  switch  provided  3  bit  power  supply  input  terminal  block, 

support  DC  input.  Voltage  input  range  is  12

48VDC  (terminal 

block  defined  as:  V-,  FG,  V+).  It  can  also  work  if  connection 

opposite. 

Communication connector

 

10/100/1000BaseT(X) Ethernet port 

The pinout of RJ45 port display as below, connect by UTP or STP. 

The  connect  distance  is  no  more  than  100m.  1000Mbps  is  used 

120Ω  of  UTP  5e;  100Mbps  is  used  120Ω  of  UTP  5;  10Mbps  is 

used 120Ω of UTP 3, 4, 5. 

 

RJ  45  port  support  automatic  MDI/MDI-X  operation.  That  can 

connect the PC, Server, Converter and HUB. Pin 1, 2, 3, 4, 5, 6, 7, 

8  Corresponding  connections  in  MDI.  1→3,  2→6,  3→1,  4→7, 

5→8,  6→2,  7→4,  8→5,  are  used  as  cross  wiring  in  the  MDI-X 

port  of  Converter  and  HUB.  In  MDI/MDI-X,  100/1000Base-TX 

PIN defines is as follows: 

PIN 

MDI 

MDI-X 

BI_DA+/TX+ 

BI_DB+/RX+ 

BI_DA-/TX- 

BI_DB-/RX- 

BI_DB+/RX+ 

BI_DA+/TX+ 

BI_DC+/

 

BI_DD+/

 

BI_DC-/

 

BI_DD-/

 

BI_DB-/RX- 

BI_DA-/TX- 

BI_DD+/

 

BI_DC+/

 

BI_DD-/

 

BI_DC-/

 

Note

 

10Base-T/100Base-TX, “TX

”transmit data

, “RX

”receive data

”not use. 

Gigabit MDI (straight-through cable) 

 

Gigabit MDI-X (Cross over cable) 

 

MDI/MDI-X  auto  connection  makes  switch  easy  to  use  for 

customers without considering the type of network cable.

 

LED Indicator

 

LED  indictor  light  on  the  front  panel  of  product,  the  function  of 

each LED is described in the table as below. 

System indication LED

 

LED 

State 

Description 

PWR 

ON 

Power is being supplied to power 

input PWR input 

OFF 

Power is 

not

 being supplied to 

power input PWR input 

LINK/ACT 

(G1~G8)

 

ON 

Port connection regular. 

Blinking 

Port connection active 

OFF 

Port had no connection. 

Installation

 

Before  installation,  confirm  that  the  work  environment  meet  the 

installation  require,  including  the  power  needs  and  abundant 

space. Whether it is close to the connection equipment and other 

equipments are prepared or not.   

1. Avoid in the sunshine, keep away from the heat fountainhead or 

the area where in intense EMI. 

2. Examine the cables and plugs that installation requirements. 

3. Examine whether the cables be seemly or not (less than 100m) 

according to reasonable scheme.   

4. Power: 12-48VDC power input 

5. Environment: working temperature: -25

70

 

Storage Temperature: -40

85

 

Relative humidity 5%

95% 

DIN Rail Installation 

In order to use in industrial environments expediently, the product 

adopt 35mm DIN-Rail installation, the installation steps as below: 

1.

 

Examine the DIN-Rail attachment 

2.

 

Examine  DIN  Rail  whether  be  firm  and  the  position  is 

1