background image

- 3 - 

suitability or not. 

3.

 

Insert  the  top  of  the  DIN-Rail  into  the  slot  just  below  the 

stiff metal spring. 

4.

 

The DIN-Rail attachment unit will snap into place as shown 

below. 

 

Wiring Requirements 

Cable laying need to meet the following requirements,

 

1.

 

It  is  needed  to  check  whether  the  type,  quantity  and 

specification  of  cable  match  the  requirement  before  cable 

laying; 

2.

 

It  is  needed  to  check  the  cable  is  damaged  or  not,  factory 

records and quality assurance booklet before cable laying; 

3.

 

The  required  cable  specification,  quantity,  direction  and 

laying position need to match construction requirements, and 

cable length depends on actual position; 

4.

 

All  the  cable  cannot  have  break-down  and  terminal  in  the 

middle; 

5.

 

Cables should be straight in the hallways and turning; 

6.

 

Cable should be straight in the groove, and cannot beyond the 

groove  in  case  of  holding  back  the  inlet  and  outlet  holes. 

Cables  should  be  banded  and  fixed  when  they  are  out  of  the 

groove; 

7.

 

User cable should be separated from the power lines. Cables, 

power  lines  and  grounding  lines  cannot  be  overlapped  and 

mixed when they are in the same groove road. When cable is 

too long, it cannot hold down other cable, but structure in the 

middle of alignment rack; 

8.

 

Pigtail  cannot  be  tied  and  swerved  as  less  as  possible. 

Swerving  radius  cannot  be  too  small  (small  swerving  causes 

terrible loss of link). Its banding should be moderate, not too 

tight, and should be separated from other cables; 

9.

 

It should have corresponding simple signal at both sides of the 

cable for maintaining. 

 

Specification

 

Technology 

Standard: IEEE802.3, IEEE802.3u, IEEE802.3x, IEEE802.3ab 

Flow control:

 

IEEE802.3x, back pressure control

 

Exchange attribute 

100M forward speed: 148810pps 

1000M forward speed: 1488100pps 

Transmit mode: store and forward 

System exchange bandwidth: 16Gbps 

MAC address table: 8K 

Memory: 1Mbit 

Interface 

Gigabit Ethernet port: 10Base-T/100Base-TX/1000 Base-TX auto 

speed control 

Transfer distance 

Twisted cable: 100M (standard CAT5/CAT5e cable) 

LED indicator 

Interface indicator: Link/ACT (G1~G8) 

Power supply indicator: PWR 

Power supply 

Input Voltage: 24VDC (12~48VDC) 

Type of input: 3 bits 7.62mm terminal block 

Support non-polarity 

Overload current protect: 4.0A   

Consumption 

No-load power consumption: 0.82W@24VDC 

Full-load power consumption: 3.65W@24VDC 

Working environment 

Working temperature: -25

70

 

Storage temperature: -40

85

 

Relative Humidity: 5%~95 %( no condensation) 

Mechanical Structure 

Shell: IP40 protect grade, metal shell 

Installation: DIN-Rail 

Weight: 0.62kg 

Size (W×H×D): 53mm×138mm×110mm 

Industry Standard 

EMI: FCC Part 15, CISPR (EN55022) class A   

EMS: EN61000-4-2 (ESD), Level 2 

EN61000-4-3 (RS), Level 2 

EN61000-4-4 (EFT), Level 2 

EN61000-4-5 (Surge), Level 2 

EN61000-4-6 (CS), Level 2 

EN61000-4-8, Level 2 

Shock: IEC 60068-2-27 

Free fall: IEC 60068-2-32 

Vibration: IEC 60068-2-6   

Certification 

CE, FCC, RoHS, UL508 (Pending) 

Warranty: 

3 years 

 