4CH SD MDVR 2001 SERIES
20 / 30
IO
Enable: incl. “OFF, Emergency, Front Door, Middle Door, Back Door, Driver Door, Other
Door, Near Beam, Distant Beam, Right Beam, Left Beam, Braking, Reverse, Fog Lamp,
Position Light, Horn, Air Conditioner, Neutral Gear, Retarder, ABS, Heater, Clutch, Door
Sensor, Smoke Sensor, Customize”
Elec: the “Electrical level”. User defined whether high or low electrical level treated as
alarm. By default, 0~4V is low level, 4~25V is high level.
Delay: the set period ensures only one alarm is processed during the set period, instead of
the same alarm be read more than once, which is especially useful when a same alarm be
triggered too frequently or wrongly triggered in a short time.
Record: enable or disable
recording when there’s alarms
ALM Link: means ”alarm linkage”. OFF or user defined to an external device like alarm
lamp etc.
View: assign a channel for alarm live video with full screen image.
HoldTime: be treated as an alarm when alarm length surpassing the set period.
SPEED