Pr.050
Setting for action of electronic thermal relay d0000: Active with standard motor
d0001: Active with special motor
d0002: Inactive
d0002
Pr.051
Setting for the time of action from electronic
thermal relay
d0030—d0300 s
d0060
Pr.052
Over-torque
detection setting
Over-torque detection
function setting
d0000: Over-torque no detection
d0000
d0001: Constant speed operation,
operation halted after over-torque
d0002: Constant speed operation,
operation continues after
over-torque detection
d0003: Operation halted after
over-torque detection
d0004: Operation continues after
over-torque detection
Pr.053
Over-torque detection
d0030—d0200
%
d0150
Pr.054
Over-torque detection
time
d000.1—d010.0 s
d000.1
Pr.055
Energy brake
setting
d0001—d9999
d0000
Pr.056
Count
attained
setting
Count attained setting
d0001—d9999
d0000
Pr.057
Function display
Output physical setting
d0000: Displays the actual
operating freq. (H)
d0001
:
Displays the actual
operating running speed (H)
d0002
:
display the user defined
setting
(
V
)
d0003
:
display the value of the
internal counter
(
C
)
d0000
Pr.058
Proportionality constant setting
d000.1—d200.0
d001.0
Pr.059
Skip frequency setting, Skip Frequency 1
d000.0—d120.0 Hz
d000.0
Pr.060
Skip frequency setting, Skip Frequency 2
d000.0—d120.0 Hz
d000.0
Pr.061
Skip frequency setting, Skip Frequency 3
d000.0—d120.0 Hz
d000.0
Pr.062
Skip Frequency band
d000.1—d020.0 Hz
d000.1