Shenzhen danfly technology co.,ltd
0755-29524002
13510025117
22
Pr.063
PWM Frequency setting
d0000
:
FPWM=2.9KHz,
d0001
:
FPWM=5.8KHz
d0000
Pr.064
Auto reset after fault
d0000—d0010
d0000
Pr.065
First fault record
d0000: Fault records clear (No errors occurred )
d0000
d0001: Over-current (oc)
d0002: Over-voltage (ov)
d0003: Overheat (oH)
d0004: Overload (oL)
d0005: Overload 1 (oL1)
d0006: External fault (EF)
d0007: CPU failure 1 (CF1)
d0008: CPU Failure 3 (CF3)
d0009: Hardware protection failure (HPF)
d0010: O.C. during acceleration (ocA)
d0011: O.C. during deceleration (ocd)
d0012: O.C. during steady state operation (ocn)
d0013: Ground fault or fuse failure (GFF)
d0014-16: Reserved for manufacture diagnosis
d0017: External base block (bb)
d0018: Overload 2 (oL2)
d0019-20: Reserved for manufacture diagnosis
Pr.066
Second fault
record
d0000
Pr.067
Third fault record
d0000
Pr.068
Parameter lock
/ restore setting
d0000: parameters can be written and read
(need 5 to 10 minutes to reset)
d0000
d0001: parameters are read only
d0002-d0009: Reserved
d0010:Restore HQM when Pr.68 = 10
d0011: Reserved
d0012: Reserved
d0019:General modes (need 5-10s to restore)
Pr.069
Baud rate
d0000—d0016
d0002
Pr.070
Contact address
d0000—d0031
d00001
Pr.071 Exclusive mode
d0000 HQM model
d0001 ZS model
d0002 MD model
d0003-d0004 reserved
d0009 general model
d0000
Pr.072
AVR output function select
d0000: disable
d0001
d0001: enable
Pr.073
Acceleration time 1
d000.1—d99.99 s
d00.02