Shenzhen danfly technology co.,ltd
0755-29524002
13510025117
25
Pr.149
Pr.150
Pr.151
Pr.152
Pr.153 AUTO PLC
d0000: internal PLC invalid
d0001:program
operation
stop
after 1 week
d0002:cycle operation
d0003:Auto operation stop after
1 week
d0004:Auto and cycle operation
d0000
Pr.153 PLC direction(internal 10 speed modes,0
refers FWD
1refers REV
first speed is
the lowest level , 1000000000 refers the
10
th
speed is REV ,other speed is FWD
d0000- -d1023
d0000
Pr.154 AUTO PLC memory function (this data
determines the pause function)
d0000:no memory
d0001:memory
d0000
Pr.155 Timer 1
d000.0- -d999.9
d000.0
Pr.156 Timer 2
d000.0- -d999.9
d000.0
Pr.157 Timer 3
d000.0- -d999.9
d000.0
Pr.158 Timer 4
d000.0- -d999.9
d000.0
Pr.159 Timer 5
d000.0- -d999.9
d000.0
Pr.160 Timer 6
d000.0- -d999.9
d000.0
Pr.161 Timer 7
d000.0- -d999.9
d000.0
Pr.162 Timer 8
d000.0- -d999.9
d000.0
Pr.163 Timer 9
d000.0- -d999.9
d000.0
Pr.164 Timer 10
d000.0- -d999.9
d000.0
七、
Troubleshooting and Fault Information
Fault code
Error and solution
Er.
0
Input voltage is lower than 150VAC .
Please ensure the working voltage is 150VAC-280VAC
Er.
1
Input voltage is over than 280VAC.
Please ensure the working voltage is 150VAC-280VAC
Er.
2
motor is over current. The motor is short circuit or overload ,otherwise need to repair
Er.
3
PWM circuit error, should power off for one minute. Then restart motor, if same error
appears ,please repair the inverter