Shenzhen danfly technology co.,ltd
0755-29524002
13510025117
26
Er.
4
IPM failure reasons:
1
.
Low Gate drive voltage, need repair
2
.
Over current, check the motor for short circuit or overload
3
.
Over hot, check the motor for short circuit or overload
Er.
5
Input signal is valid when external failure and motor is not working
Er.
6
Internal data storage error. Power off for 1 minute then restart motor. If same error
appears ,need to repair.
Er.
7
Lifetime is finished. Please contact supplier
Er.
8
Over current at acceleration or deceleration. Please increase the deceleration time.
Or change bigger power inverter.
Er.
9
Over current at running, machine is overload,please change bigger power inverter.
Er.
10
Communication code error.
Er. 11
Communication data error
Er. 12
Communication timeout
Er. 13
Communication calibration error
No display
,power
indicator
flash
1. check input power, ensure the voltage is 150 to 250V AC, otherwise need to
repair
2. internal power supply detection, need to repair.
No display
,power
indicator
dark
check input power, ensure the voltage is 150 to 250V AC, otherwise need to repair
Quality and Guarantee
Quality assurance in accordance with the following provisions:
6.1 12months warranty
6.2 Offer lifelong paid service
6.3 Below failures is not guaranteed
1. Improper operation or repair without permission
2. Man-made damage
3. Aging or failure caused by bad environment Or natural disasters.
4. damage during transportation.
5. trademark or label is damaged