Operational Control
Intelligent temperature controller with more perfect control system,
control the time delay of compressor, fan and on/off, defrosting
temperature into the Settings, defrosting quit. the temperature of the
cooling and heating operation process by time and temperature of double
protection self-checking overheat detection, sensor self-inspection (E1
said sensor fault line), the operation is simple, powerful.
After the machine
power
on, open the switch, panel auto-matically detect
probe the relationship between temperature and set temperature, etermine
the machine cooling or heating mode
(
the
machine
is only
cooling
,
and
standby
mode
).
When the water temperature is greater than the set temper-ature more
than 2
°
C/
°
F
,
the
machine
start
delay
cooling mode operation
after
three
minutes
.
When
the
water
temperature
is
less
than
the
set
temperature
below
2
°
C/
°
F
,
the
machine
start
delay
heating mode operation
after
three
minutes
.
When
the
water
temperature
and
set
temperature
within
2
°
C/
°
F
,
standby
the
machine
.
Temperature
once
set
,
the
parameters
are
stored
,
if
not
reset
,
the
machine
has
been
operating
and
stop
to
set
temperature
.
The chiller has power failure memory function. Call again after the
blackout, still in accordance with the mode of the original machine.
The chiller
has the compressor delay start protection function. Stop after
restarting, if the downtime is less than 3 minutes, automatic control system
delay to meet 3 minutes
after the restart.
See illustration on the control panel 1~2.
Press and hold the SET into the function of temperature setting,
adjusted by
“▲”
key
or
“▼”
key until
conform
to
the
requirements
of
the
owner
.
Stop the operation (don't press any keys) for 10 seconds, automatically
converted to digital tube display temperature, set up effective.
3